background image

 

Motorisation of Window Coverings 

using Somfy Motors

 

 

 

Integration to BMS using LS40 or LT50 

 

Option 1 

CD4 individual motor controller 

• 

Requires 240V power supply and has 240V latched output 

• 

Provides interlocking between up and down commands 

• 

Dry contact impulse switching (impulse contact closure of 1 second minimum) 

• 

Contact between common and up or common and down to activate motor 

• 

Simultaneous contact between a common up and down to create a stop 

• 

CD4 Venetian module available for control of Venetian blinds 

• 

Dimensions: 112 (h) x 52 (w) x 106 (d) 

 

 

Note: Earth wire not required for LS40 motors 

Содержание ALTUS 50

Страница 1: ...Motorisation of Window Coverings using Somfy Motors...

Страница 2: ...ncipal The motor drives the wheel The wheel drives the roller tube The roller tube drives the crown The crown drives the limit switch within the motor ATTENTION Somfy Motors are not waterproof Do not...

Страница 3: ...Cable length 2 5m Cable size 3 x 0 75 Important LS40 motors must never be wired in parallel Damage caused by parallel wiring will not be covered under warranty LT50 Motor Suitable for roller blinds an...

Страница 4: ...mand Cable length 2m Cable size Flat 4 core multistrand date cable Nominal Supply Voltage 220 240V Current consumption at nominal torque 270 watts maximum Running Current 1 2 amps maximum Altus 40 Mot...

Страница 5: ...rown Active Green Yellow Earth Nominal Supply Voltage 220 240V Current consumption at nominal torque 270 watts maximum Running Current 1 2 amps maximum Cable length 3m Cable size 3 x 0 75 Concept 25 M...

Страница 6: ...utdoor installations Do Not use other switches and controls other than those recommended by Somfy When using a Somfy control box plug in type make sure the power supply is switched off before plugging...

Страница 7: ...e motors A will stop at its pre set limit before the other B Current from motor B will then flow back through to motor A through capacitor C2 and micro switches M3 and M1 There will be constant feedba...

Страница 8: ...des interlocking between up and down commands Dry contact impulse switching impulse contact closure of 1 second minimum Contact between common and up or common and down to activate motor Simultaneous...

Страница 9: ...ween a common up and down to create a stop ML9000 Power supply and master controller Can control up to 16 individual motor controllers Dimensions 85 h x 70 w x 62 d 4 DIN rail slots ML8000 Individual...

Страница 10: ...es interlocking between up and down commands Dry contact impulse switching impulse contact closure of 1 second minimum Contact between common and up or common and down to activate motor Simultaneous c...

Страница 11: ...Allows for connection between RJ11 connector and standard data cable Dry contact impulse switching impulse contact closure of 1 second minimum Contact between common and up or common and down to acti...

Страница 12: ...nimum Contact between common and up or common and down to activate motor Simultaneous contact between a common up and down to create a stop One transmitter for each command required Transmission range...

Страница 13: ...ween a common up and down to create a stop RS232 connection o Bits per Second 1200 o Data bits 8 o Parity None o Stop Bits 1 o Flow Control Hardware o Commands U1 Up Command Channel 1 S1 Stop Command...

Страница 14: ...Motorisation of Window Coverings using Somfy Motors Option 2 cont Busline Transmitter Five channel...

Страница 15: ...oncept 25 IRS 300 Supply voltage 24V DC Dry contact impulse switching impulse contact closure of 5 seconds minimum Contact between common and up or common and down to activate motor Simultaneous conta...