background image

inteo

SOLIRIS RTS

24V

sensor

Installation Instructions

Power supply :

Operating temperature :

-20

The

must be supplied by a class 2 transformer

SOLIRIS RTS

0

24V AC/DC

25 mA at 24V DC

Rated Current :

-4 F to 122 F/

C to +50 C

sensor

0

0

0

24V SOLIRIS RTS SENSOR KIT

CAT NO. 6301051

(

includes transformer, not shown)

Installation

1

Dimensions

9.3 in./236 mm

6.3

in./160

mm

x

x

x

Sun Sensor

Wind Sensor

x

x

x

The

is a radio sun & wind sensor for awnings.

The wind and sun thresholds can be set directly on the
The

is compatible with the

and

motors only.

SOLIRIS RTS

SOLIRIS RTS

.

SOLIRIS RTS

LT RTS CMO

ALTUS RTS

sensor

sensor

sensor

SOMFY SYSTEMS, INC. reserves the
right to update, change or modify
these instructions without prior notice.

REF. NO: 182449A

COPYRIGHT C SOMFY SYSTEMS, INC.

4/02

SOMFY SYSTEMS, INC.

47 Commerce Drive
Cranbury, NJ 08512

SOMFY CANADA

6315 Shawson Drive, Unit #1
Mississauga, Ontario L5T1J2

SOMFY MEXICO S.A. De C.V.

Calle 3 No. 47, Loc. E-5
Fracc Ind. Alce Blanco
Nau., Edo. de Mex C.P. 53370

Wiring

2

1. Remove Cover and unscrew
plate over wiring compartment

UP
STOP
DOWN

2. Loosen the strain relief
plate and guide the power
supply wires through
the black grommet into
terminal block.

3. Connect the cable leads to the terminals
- Terminal block is removable for easier

connections, and the input power is
not polarized.

WARNING:

For the

to function properly,

the transmitter which is memorized into the motor's receiver,
must be configured correctly. The DOWN button MUST correspond
to DOWN on the end product. In the case of an awning, it will open
or extend the awning. If the UP button extends the awning, the
wind sensor will also extend the awning during windy conditions.
THIS IS DANGEROUS! Damage and injury could occur. Do not
proceed until proper operation of the transmitter is verified. Please
refer to the installation instructions of the relevant motor to change
the direction if necessary.

SOLIRIS RTS SENSOR

grommets

strain
relief

TO 24V AC/DC
TRANSFORMER

TO 24V AC/DC
TRANSFORMER

x

x

4. Replace wire
compartment cover

5. Attach the sensor to the wall.
Replace front cover and secure
with screws provided

A. Power input to the sensor is not polarized,
but turn off the power and fully discharge
the transformer before making final connections.
B. The cable distance between the power supply
and the sensor must not exceed 164 feet.