E1UC-4
Quad Stream E1 Switch/Groomer
Installation and Operation
3-4
Timing and Synchronization
E1UC presumes that data for all streams are synchronous to
each other, that is to say, that they are all running on the
same clock source.
Input 1 is considered to be the Master input. If a stream that is
from a different clock domain is plugged into another stream,
the data integrity of that stream will be compromised. Padding
frames may be inserted in the case that the rate of this stream
is lower than that of the master input. If this stream’s rate is
higher than the master stream, whole frames may be
discarded.
If only one stream is to be used, this should be connected to
Input 1.
Master input