Solwise PL-200AV-PEW Скачать руководство пользователя страница 1

 

 
 

PL-200AV-PEW   

USER MANUAL 

 

 

 

 

 

 

 

 

 

 

 

Содержание PL-200AV-PEW

Страница 1: ...PL 200AV PEW USER MANUAL...

Страница 2: ...IP Properties 7 4 2 Login 7 4 3 Overview 8 4 4 LAN 9 4 5 Wireless 10 4 6 Security 11 4 7 Management 13 5 Installing PLC Utility Software 14 6 How to Use the Utility Software 16 6 1 Main Page 16 6 2 Pr...

Страница 3: ...cations No cables no drilling These adapters enable the effortless creation of a high speed network that supports video voice and data 1 1 Features Wallmount type and power voltage range of 100 V to 2...

Страница 4: ...2 Free Disk Space At least 20MB Network Interface At least one fast Ethernet 100 Mbps network card and Ethernet cord 1 3 Package Contents PL 200AV PEW x 1 CD ROM x 1 RJ45 Ethernet cable x 1...

Страница 5: ...not operate this product near water This product should never be placed near or over a radiator or heat register Do not use an extension cord between the device and the AC power source Only a qualifie...

Страница 6: ...thernet network cable The other end of the cable will connect to your computer or other Ethernet enabled network device 3 2 The Adapter s Buttons Button Description Reset The Reset button is used to r...

Страница 7: ...t indicates that the device is ready for use Power Green Red Flash When the LED is orange it indicates that the device is loading firmware On When the PLC indicator is green it indicates that powerlin...

Страница 8: ...the PL 200AV PEW Step 1 Put the PL 200AV PEW to the AC power socket directly Step 2 Use one end of Ethernet network cable to connect to the PL 200AV PEW Ethernet port and another end connect to your...

Страница 9: ...e the Access Point through Web page 4 1 Setting TCP IP Properties The default IP address of PL 200AV PEW is 192 168 1 1 you should set your PC s IP address in the same subnet 4 2 Login Open IE and ent...

Страница 10: ...efault password is password Click OK to log in to the web page otherwise click Cancel to exit 4 3 Overview After finish login the default page Overview appears The Overview page displays the current s...

Страница 11: ...less network settings WLAN MAC Address The physics address of Wi Fi interface This field shows the packets statistic information of Wi Fi module Click Update to refresh the statistic information 4 4 L...

Страница 12: ...s Pool The IP address range that DHCP Server leases to After finishing the settings above click Apply and then the new settings take effect The Wi Fi module saves all changes to Flash Click Cancel to...

Страница 13: ...s big it can help to save power The interval time range is between 25 and 500 The default value is 100 Data Rate It is the wireless physics rate It is highly recommended that you select Auto If you se...

Страница 14: ...y authentication the sender and recipient use a WEP key for authentication In most cases please keep the default value If you select Open System Shared Key or Open Shared mode you may configure VAP WE...

Страница 15: ...ur PC Click Upgrade to download the new firmware to the device Restore Factory Defaults Click the Restore button then the all current configuration returns to factory default Click the Save button the...

Страница 16: ...Powerline Utility installed on your computer If there is another utility installed please uninstall it and restart your computer Please insert the utility CD ROM into the computer s CD ROM drive Doub...

Страница 17: ...15 Click Browse to select the installation folder and then click Next to continue Click Close to finish the installation...

Страница 18: ...o the local devices Once connected to the local device the utility will automatically scan the power line periodically for any other HomePlug devices If no local HomePlug devices are discovered the st...

Страница 19: ...is blank Click Enter Password button user may modify the password To set the Password of the device It is necessary when creating a private network first select the device by clicking on its name and...

Страница 20: ...the device A Add Device to Network dialog box appears You are allowed to set the device name and the password A confirmation box will appear if the password was entered correctly and if the device was...

Страница 21: ...will be shown Scan This button is used to search the HomePlug devices connected to the Powerline network By default the utility automatically scans every few seconds and updates the information 6 2 Pr...

Страница 22: ...by clicking on the Use Default Public Network button Note Changing the network name to anything other than HomePlug the main page will show the network type as Private Set Local Device Only This butto...

Страница 23: ...that appear on the main page whose Device s Password had been entered in the same logical network After finishing modifying a dialog box appears to remind you that the operation is successful If the d...

Страница 24: ...puter over a certain period of time All devices that were on the powerline network are listed here along with a few other parameters Devices that are active on the current logical network will show a...

Страница 25: ...x pops up with a confirmation message if we try to delete a device whose password has been entered 6 4 About page The About screen shows the software version and provides a HTML link to the manufactor...

Страница 26: ...can follow the steps below Step 1 Press the SECURITY button on the first device A for less than 3 seconds Step 2 Press the SECURITY button on the second device B for less than 3 seconds The button on...

Страница 27: ...K from B 7 2 Joining a Network In this scenario a network exists a new device the joiner wants to join the network Any device on the existing network can become the adder Step 1 Press the pushbutton o...

Страница 28: ...A network exists The user wants to remove one device the leaver from that network for whatever reason He may want to remove the device from service altogether or have it join another logical network S...

Страница 29: ...ave the AVLN Press NMK button on A more than 10 sec A computes random NMK C resets and restarts A PLC A PLC B PLC B PLC C PLC A B and C form an AVLN A wants to leave the AVLN Press NMK button on A mor...

Страница 30: ...d ROBO Encryption 128 bit AES QoS Support contention free access four level priority based contention access and multi segment bursting Support VLAN Priority Support ToS and CoS Packet Classifier Work...

Страница 31: ...et Reset system or restore the factory defaults Security Used to set the membership state Ethernet Interface 1 x RJ45 for 10 100 Ethernet Auto MDI MDI X Consumption 5 5W Max Environment Requirement Op...

Страница 32: ...entifiers CSMA CA Carrier Sense Multiple Access Collision Avoidance DAK Device Access Key IGMP Internet Group Management Protocol NEK Network Encryption Key NID Network ID Identification SECURITY Netw...

Страница 33: ...to a host IGMP default CAP 3 sets the channel access priority for IGMP frames these are the group management frames not the stream data Unicast default CAP 1 sets the default channel access priority...

Страница 34: ...32 4 CAP2 4 CAP2 5 CAP2 5 CAP2 6 CAP3 6 CAP3 7 CAP3 7 CAP3...