Page 4 / 17
TROUBLESHOOTING
PROBLEM
CAUSE AND REMEDY
The appliance does not switch on There is no voltage.
Check the main switch and/or the electrical connections.
The impeller does not turn
Check that its movement is not obstructed.
This device is equipped with a manual reset protection system
that in the event of a mechanical obstruction in the rotation will
switch off the engine.
To restore normal operation, proceed as follows:
disconnect the device from the power mains upstream;
remove the cause of the mechanical obstruction (only
qualified
personnel);
reconnect the device to the power mains.
The device will only resume normal operation if the protection
system does not detect any additional faults. If the fault persists,
contact the client support service.
The devices on the PLUS RC version
do not synchronise
Disconnect and reconnect power supply.
The remote control does not work
(only in the Plus RC version)
Check the status of the battery.
DISMANTLING AND RECYCLING
If a crossed-out wheeled bin is illustrated on a product, this means that the product satisfies the
requirements of the 2012/19/UE European Directive.
Conform to the local norms regarding the disposal of waste materials and do not dispose of old
products in normal domestic waste material.
PRODUCT DESCRIPTION
The product is a single hole, heat recovery unit without ducting, suitable for single rooms.
The heat is recovered by means of a ceramic exchange that acts as a heat accumulator. In the normal
operating cycle, the device expels stale air from the inside outwards (extraction); in this first phase the air passes
through the recuperator transferring heat to the ceramic core. In the second phase of the cycle the air flow is
reversed (intake): the external air passes through the heat exchanger capturing the previously accumulated
heat before being transferred inside. This operation alternates the flow every 60 seconds (Push-Pull).