TROUBLESHOOTING 

 
PROBLEM 

CAUSE AND REMEDY 

The appliance does not switch on  There is no voltage. 

Check the main switch and/or the electrical connections. 

The impeller does not turn 

Check that its movement is not obstructed. 
This device is equipped with a manual reset protection system 
that in the event of a mechanical obstruction in the rotation will 
switch off the engine. 
To restore normal operation, proceed as follows: 
disconnect the device from the power mains upstream; 
remove the cause of the mechanical obstruction (only 
qualified 
personnel); 
reconnect the device to the power mains. 
The device will only resume normal operation if the protection 
system does not detect any additional faults. If the fault persists, 
contact the client support service. 

The devices on the PLUS RC version 
do not synchronise 

Disconnect and reconnect power supply. 

The remote control does not work 
(only in the Plus RC version) 

Check the status of the battery. 

 
 
 
 

DISMANTLING AND RECYCLING 

 

If a crossed-out wheeled bin is illustrated on a product, this means that the product satisfies the 
requirements of the 2012/19/UE European Directive. 
Conform to the local norms regarding the disposal of waste materials and do not dispose of old 
products in normal domestic waste material. 

 
 
 
 

PRODUCT DESCRIPTION 

 
The product is a single hole, heat recovery unit without ducting, suitable for single rooms. 
The heat is recovered by means of a ceramic exchange that acts as a heat accumulator. In the normal 
operating cycle, the device expels stale air from the inside outwards (extraction); in this first phase the air passes 
through the recuperator transferring heat to the ceramic core. In the second phase of the cycle the air flow is 
reversed (intake): the external air passes through the heat exchanger capturing the previously accumulated 
heat before being transferred inside. This operation alternates the flow every 60 seconds (Push-Pull).  

 

 

Содержание elicent REC-Duo 100

Страница 1: ...recovery unit Instruction Manual ENGLISH v1 4 WARNING The equipment must only be installed by a specialised technician Read and apply the manual before carrying out the installation Keep this manual i...

Страница 2: ...ogy and respects the standards in force regarding electrical equipment It conforms with the EMC European Directive in force regarding radio interference suppression and electro magnetic compatibility...

Страница 3: ...es precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances Toavoid the risk of fire do not using the product in the presence...

Страница 4: ...y The remote control does not work only in the Plus RC version Check the status of the battery DISMANTLING AND RECYCLING If a crossed out wheeled bin is illustrated on a product this means that the pr...

Страница 5: ...Page 5 17 OPERATING PRINCIPLE Extraction Cycle Push Intake Cycle Pull 60 seconds 60 seconds DIMENSIONS Main Unit REC Duo 100 EXTERNAL VENT EXTERNAL COWLING PLENUM...

Страница 6: ...ready assembled on the heat exchanger 8 Screws for fixing the wall power supply plate cover 9 Wall plugs 10 Screws for fixing power supply plate 11 Awl key for RESET button 12 Remote Control 1pc RC ve...

Страница 7: ...be considered to install the duct without cowling For retrofit projects we recommend to use always the cowling to allow a correct installation of the trade seal The Wall Mounting Bracket and the REC...

Страница 8: ...INSTALLATION ADVICES Wall Mounting Bracket Hole Diameter 110 mm External Waterproof Membrane Tube External Cowling Plenum Drill or cut a 110mm hole through wall with a 2 slope towards outside If requi...

Страница 9: ...go through power supply plate Switch is not included After installing the gib board over the mounting wall bracket cut out the whole and line up the power supply plate on top Connect power supply pla...

Страница 10: ...ude a main switch to power off the whole unit for e g maintenance Insert the REC Duo unit into the duct The power connectors need to line up and the plate snaps into a magnetic mount Complete external...

Страница 11: ...d to set the timer operating time only extraction from 0 to 30 minutes HY Humidistat This function is present in the REC DUO 100 MHY and REC DUO 100 PLUS RC models Adjust the trimmer HY screw blue to...

Страница 12: ...ned alternating rotation direction They will not need to be re synchronised REC Duo 100 PLUS RC For optimum operation installation in pairs is recommended up to a maximum of 6 devices DEVICE PAIRING O...

Страница 13: ...G THE REMOTE CONTROL Remove the transparent pull tab from the remote control battery compartment The remote control is enabled to operate in a radius of approximately 20m with the battery in a good fu...

Страница 14: ...signal SPEED ADJUSTMENT 2 KEYS 3 Speed 2 can be set between 70 and 100 In the factory settings mode this value is approximately 90 The setup is reflected on all synchronised machines Sequence 1 Selec...

Страница 15: ...djustable timer is provided for setting maximum speed boost duration from 0 to 30 minutes see paragraph TIMER AND HUMIDISTAT At the end of the timer cycle the unit automatically returns to the pre set...

Страница 16: ...E COOLING RC BUTTON 7 FLASHING YELLOW OR GREEN FORCED FLOW OPERATING RC Button 6 FLASHING WHITE LIGHT BLUE RECEIVING COMMAND FROM RC FLASHING RED PURPLE RESTORE FACTORY SETTINGS PURPLE LED INTENSITY A...

Страница 17: ...E REPLACE CLEAN FILTERS NOTICE RED FLASHING LED Press the button RESET located at the base of the front support of the ventilation unit for more than 5 seconds When the LEDs turn violet the reset succ...

Отзывы: