Installation Manual 

 
 
 

Battery Energy Storage System 

 
 
 

Soluna S12 EU-A50 

 
 
 

DLG Energy (Shanghai) Co., Ltd. 

 

 
 
 
 

June 2020 Version V1.1 

 

Содержание S12 EU-A50

Страница 1: ...Page 1 of 60 Installation Manual Battery Energy Storage System Soluna S12 EU A50 DLG Energy Shanghai Co Ltd June 2020 Version V1 1...

Страница 2: ...s accurate at the time of publication Regarding the product design and technical specification updates our company reserves the right to make changes at any time without prior notice Also the illustra...

Страница 3: ...stallation tools 22 Spacing during installation and operation 23 Wiring specifications 24 Installation step 24 Unpacking confirmation 24 Basic installation requirement 25 Installation procedures 26 St...

Страница 4: ...liable for any consequence caused by any of the following events Damage caused by transportation The storage conditions do not meet the requirements specified in the manual resulting in damage Incorr...

Страница 5: ...d in this manual Sign Name Description Danger Severe physical injury or even death may occur if related requirements are not followed Warning Physical injury or damage to the devices may occur if rela...

Страница 6: ...dards Ground with proper technics before the operation Do not open the surface cover of the system unless authorized The electronic components inside the system are electrostatic sensitive Do take pro...

Страница 7: ...ve materials Do not install the system in a place where children and other people can easily touch it To avoid the risk of electric shock please remove rings bracelets and other metal jewellery on you...

Страница 8: ...ents not provided by our company during maintenance Restart the system after eliminating the faults and problemswhich may affect the safety and performance of the system Do not get close to or touch a...

Страница 9: ...quired reducing electricity bills improving the household energy self consumption and working when there is a BLACKOUT A Soluna BESS will provide the solution Features Intelligent power management Sim...

Страница 10: ...Page 10 of 60 Outline Dimensions Figure 2 1 outline dimension Width 750 mm Depth 565 mm Height 1335 mm Weight 300 kg...

Страница 11: ...Page 11 of 60 Functional description The basic principle of Soluna S12 EU A50 Figure2 2 basic principle of Soluna S12 EU...

Страница 12: ...the Grid will supplement Mode 3 If there is a Grid failure or in an off Grid region the PV and battery can power the loads together Mode 4 When the battery is low and the PV power is unavailable the...

Страница 13: ...activated it will sink reactive power in response to an increasing voltage inductive and supply reactive power in response to a decrease in voltage capacitive The voltage at which the inverter should...

Страница 14: ...s to 265V the inverter output power will gradually decrease When the voltage reaches to 265V its output power will decrease to 20 of Pstart This mode is not enabled by default and will reduce the outp...

Страница 15: ...nd response commands from grid company and then adjust inverter output power The Earth fault alarm Before the inverter starts to connect to the grid the inverter will first detect the impedance of PV...

Страница 16: ...50 Max AC output current A 25A Max AC input current A 25A Max continuous Power kW 5kW Power factor range 0 8 0 8 Off Grid AC Output Normal Voltage VAC 230 Single phase L N PE Frequency Hz 50Hz Max AC...

Страница 17: ...tes IEC62109 CE LVD EN 62477 1 2012 ALL 2014 Warranty Please refer to SOLUNA WARRANTY CONDITIONS Technical Data of the battery module Physical Characteristics Width 205 mm Depth 678 mm Height 436 mm W...

Страница 18: ...itions Installation Location Indoor Operating Temperature 10 45 Operating Temperature Recommended 15 30 Storage Temperature 20 60 Humidity 5 95 Altitude Max 2 000 m Cooling Strategy Natural Convection...

Страница 19: ...Page 19 of 60 Appearance Figure 2 3 Appearance Number Name Remark Soluna brand LCD panel...

Страница 20: ...Page 20 of 60...

Страница 21: ...Page 21 of 60 Figure 2 5 Appearance Number Name Remark The door lock of the system The door key...

Страница 22: ...Page 22 of 60 Installation Installation tools...

Страница 23: ...ESS During operation Position Min spacing Remark Side spacing 100cm There needs to be a clearance of 100cm on either side of the Soluna BESS Backspacing 10cm It needs to be installed against the wall...

Страница 24: ...of the package box and whether the product package is intact If there is any question please contact the supplier timely Store the idled system in its original packaging and take anti moisture and an...

Страница 25: ...n floor shall be dry and flat It is strictly forbidden to have wateron the ground ensure that the ground can adequately withstand the weight of the BESS cabinet The temperature in the installation env...

Страница 26: ...procedures The mechanical installation steps are as follows Step 1 Remove the S12 EU A50 casing and the battery modules from the packaging box Figure 3 1 battery module system case Number Name Remark...

Страница 27: ...Page 27 of 60 Step 2 The casing is attached to a wall Figure 3 Attached the casing to the wall Number Name Remark Wall Soluna System Expansion Screw Fixed Bracket Ground...

Страница 28: ...Page 28 of 60 Step 3 Open the door of Soluna system and open the case of the battery module Figure 3 4 Battery Unit Number Name Remark System case Case of Battery module...

Страница 29: ...terminal Number Name Remark Remote wire Battery cable CAN communication line Remark Connecting wire for communication line 1 All CAN1 lines are parallel for the internal communication of battery unit...

Страница 30: ...Page 30 of 60 Step 5 Fixed battery module and close the door of the BESS Figure 3 7 Fixed battery module Number Name Remark M6 12 Combination screw Fixed bracket...

Страница 31: ...31 of 60 Step 6 External circuit connection PV GRID LOAD Figure 3 8 External circuit connection Number Name Remark Emergency Stop Load connector Grid connector GEN connector PV connector GEN control...

Страница 32: ...t the maximum open circuit voltage of each PV string is not higher than the maximum input voltage of the BESS under any circumstances It is forbidden to connect the PE wire ground wire to the positive...

Страница 33: ...load cables Terminal crimping torque 3 6 4 6 N m Note Before connecting the AC power Grid cable to the BESS the lightning protection and short circuit protection measures must be taken following the l...

Страница 34: ...e neutral cable of the On Grid side and Back Up side must be connected otherwise Back Up function will not work Figure A B The following diagram is an example for grid systems without special requirem...

Страница 35: ...power to check if the back up function is working to avoid potential problems for subsequent uses Figure C Remark Although the RCD is shown the Soluna system itself has the function of leakage protect...

Страница 36: ...or and turn on all the switch of Load Grid Battery Remote Turn off Open the door and turn off all the switch of Load Grid Battery Remote Please see the image of the switches below Figure 3 9 Turn on T...

Страница 37: ...erate the LCD The LCD can be found on the front of the system see image below Figure 4 0 LCD Number Name Remark LCD panel Note The LCD is operated by touch to view the information in the LCD simply to...

Страница 38: ...Status 2 Settings 3 Data 4 Production information 5 Battery capacity in the middle Figure 4 1 LCD Screen How to check the information about the PV Load Power Feed in power Battery power The user can...

Страница 39: ...Page 39 of 60 Figure 4 3 PV information Figure 4 4 Load information Figure 4 5 Grid information...

Страница 40: ...Setting parameters of Soluna system The user will find the following interface after clicking the icon of Setting Figure 4 7 Setting icon information User can find the following interface after clicki...

Страница 41: ...Page 41 of 60 Figure 4 9 Charging setting 1 Figure 4 10 Charging setting 2 Figure 4 11 Charging setting 3...

Страница 42: ...tilizations Figure 4 12 Discharging setting 1 Figure 4 13 Discharging setting 2 User can find the following interface after clicking the icon of Languages Figure 4 14 Language selection Remark There a...

Страница 43: ...the following interface after clicking the icon of reset advanced settings User needs to enter a password if the user wants to restore the parameters of the S12 EU A50 Soluna can provide the password...

Страница 44: ...ing the icon of Data Figure 4 18 Data icon The user can see the following interface after clicking the icon of Solar generation Figure 4 19 Statistics solar generation The user can find the following...

Страница 45: ...valent tree planting User can find the following interface after clicking the icon of save the earth Figure 4 22 Carbon dioxide emission reduction How to check the production information of the BESS U...

Страница 46: ...mation The user can find the fault information after click the fault icon Remark The user will find an icon blinking in the upper right corner of the LCD panel if there is any fault during Soluna syst...

Страница 47: ...uum cleaner to clear the dust and any other particles hindering the ventilation of the system Note Shut down the fan before cleaning to avoid personal injury and device damage caused by electric shock...

Страница 48: ...y volt high 40 Battery open 41 Quick stop 42 Pv1 over current hw 43 Pv2 over current hw 44 Bat over current hw 45 LLC over current hw 46 LLC over voltage hw 47 CAN comm error 48 Load overpower 49 Exte...

Страница 49: ...Page 49 of 60 Remote monitoring 1 Download APP iPhone Search Soluna in Apple Store Android Search Soluna in Google play Store Remark Please see below picture for Soluna Icon...

Страница 50: ...Page 50 of 60 2 Register Click Register to create new account you can use email to register...

Страница 51: ...Confirm your plant location GPS function will automatically determine the plant site if you want to modify the location click the map icon and then manually enter the address in box b 2 Select your pl...

Страница 52: ...Page 52 of 60 3 3 Input Plant Name It is suggested to create a plant name like location name capacity e g Soluna 8 1KW then click Done...

Страница 53: ...Page 53 of 60 3 4 Now you can see your plant on the homepage...

Страница 54: ...Page 54 of 60 4 Wi Fi Connection Configuration Select the plant and click Connect Again in the tab Device select your device and click Done to the next step...

Страница 55: ...r Android user 1 APP will automatically get your Wi Fi network so you need to enter your Wi Fi password to continue the configuration if the network is not accurate select switch network then find or...

Страница 56: ...6 of 60 2 The connection will automatically start after connect the network 3 It normally takes 3 5 minutes to configure successfully Then you can go back to tab Device and click Device to add more de...

Страница 57: ...for iOS user 1 APP will automatically get your Wi Fi network so you need to enter your Wi Fi password to continue the configuration if the network is not accurate select Switch network then find or ma...

Страница 58: ...ure Notice If it is unable to find an AP_XXXXX S N in wireless network list please make sure to shorten the distance between Wi Fi routers and stick Logger to under 10 meters the connection or setting...

Страница 59: ...sword 2 The router s network signal is weak and the logger is too far away from the router put the router closer to the logger 3 Click too fast during the Logger s AP connection Please wait a few seco...

Страница 60: ...60 Contact us If any questions please contact us DLG Energy Shanghai Co Ltd Soluna Address No 3492 Jinqian Road Shanghai China 201406 Tel 86 21 57475835 Email sales solunabattery com Web www solunaba...