SOLTEK SL-75DRV5 Скачать руководство пользователя страница 70

75DRV5

70

* Primary

Master / Slave PIO

Secondary

Master / Slave PIO

Choose Auto or Mode 0~4. The BIOS will detect the
HDD mode type automatically when you choose
Auto. You need to set to a lower mode than Auto
when your hard disk becomes unstable.
The choices: Auto; Mode 0; Mode 1; Mode 2; Mode
                      3; Mode 4.

* On-Chip IDE channel

0/1

The chipset contains a PCI IDE interface with
support from two IDE channels. Select Enabled
to  activate  the  first  and/or  the  second  IDE
interface. Select Disabled to inactivate an interface
if you install a primary and/or second add-on IDE
interface.
The choices: Enabled; Disabled.

VIA OnChip IDE Device

* IDE Prefetch Mode

The on-board IDE drive supports IDE perfecting for
faster drive accesses. If the IDE device doesn’t
support perfecting, set this field to Disabled.
The choices: Enabled; Disabled.

Item Help

Menu Level

OnChip IDE Channel0
OnChip IDE Channel1
IDE Prefetch Mode
Primary Master PIO
Primary Slave PIO
Secondary Master PIO
Secondary Slave PIO
Primary Master UDMA
Primary Slave UDMA
Secondary Master UDMA
Secondary Slave UDMA

CMOS Setup Utility - Copyright (C) 1984-2002 Award Software

VIA OnChip IDE Device

:Move  Enter:Select  +/-/PU/PD:Value  F10:Save  ESC:Exit  F1:General Help
F5:Previous Values  F6:Fail-Safe Defaults  F7:Optimized Defaults

Enabled
Enabled
Enabled
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto

Содержание SL-75DRV5

Страница 1: ...R T h e S o u l O f C o m p u t e r T e c h n o l o g y Mainboard SL 75DRV5 User Manual V2 0...

Страница 2: ...nical including photocopying and recording for any purpose without the express written permission of Soltek Computer Inc Companies and products mentioned in this manual are for identification purpose...

Страница 3: ...R O C Telephone 886 2 2642 9060 Fax 886 2 2642 9065 E mail sales soltek com tw Web site http www soltek com tw SOUL TECHNOLOGY EUROPE B V Address Hongkongstraat 55 3047 BP Rotterdam The Neth erlands...

Страница 4: ...1 1 11 Hardware Monitoring 11 1 2 Mainboard Layout 12 1 3 Chipset Diagram 13 Chapter 2 Hardware Setup 15 2 1 CPU Installation 16 2 2 Memory Installation 17 2 3 AGP 4X Accelerated Graphics Port Install...

Страница 5: ...Complex Header 34 2 7 6 ATX Power Supply Connector 35 2 7 7 Chassis Panel Connectors 36 2 7 8 PS 2 Mouse And PS 2 Keyboard 36 2 7 9 Smart Card Reader Connector SCR1 37 2 7 10 Communication And Network...

Страница 6: ...Features 63 4 6 5 Integrated Peripherals 69 4 6 6 Power Management Setup 75 4 6 7 PnP PCI Configuration 81 4 6 8 SmartDoc Anti Burn Shield 84 4 6 9 Frequency Voltage Control 87 4 6 10 Load Optimized...

Страница 7: ...tent Mainboard Support CD User s Manual Bundled Bonus Pack CD Bundled Bonus Pack Manual Temperature Sensor Cable Optional ATA66 100 133 IDE Cable RS232 Cable FDD Cable USB Cable Optional ITEM LIST CHE...

Страница 8: ...nboard Layout 1 3 Chipset Diagram This chapter briefly introduces the characteristics of the mainboards It includes the information regarding the chipset CPU types built in functions and layout Users...

Страница 9: ...I O 1 1 3 AWARD BIOS V6 0 Supporting Plug Play V1 0 Flash Memory for easy upgrade Year 2000 compliant BIOS writing protection TrueBlue Anti Burn shield 1 1 4 Sound Controller SoundBlaster Pro Hardware...

Страница 10: ...parallel connector supporting Standard mode ECP and EPP Floppy Disk connector supporting One FDD with drive swap function Universal Serial Bus connector supporting USB v1 1 and Intel Universal HCI v1...

Страница 11: ...ardware Monitoring Programmable control status to provide monitoring and alarm for flexible desktop management software include 5 positive voltage statuses monitoring 2 temperatures statuses monitorin...

Страница 12: ...IDE1 IDE2 Li Battery FAN3 1 3 FAN4 1 3 FAN2 FAN1 1 3 RT1 FAN5 1 3 VIA VT8233A FDC1 USB0 USB1 PS 2 MOUSE PS 2 K B LPT1 COM1 COM2 GAME MIDI PORT MIC LINE OUT LINE IN SW1 ON DIP 1 2 3 4 5 FLASH BIOS LPC...

Страница 13: ...ock Using the VT8233A V Link South Bridge DDR Vlink Host North 552 BGA VT8233A Vlink Client South 352 BGA 3D Graphics Controller Athlon Host CPU SDR VCM DDR SDRAM Clock Buffer Clock Generator SDR DDR...

Страница 14: ...14 75DRV5 MEMO MEMO...

Страница 15: ...Please refer to your processor installation or other documentation attached to your CPU for detailed in stalling instruction 2 Installing a heat sink and cooling fan is necessary for proper heat dissi...

Страница 16: ...onent 2 1 CPU Installation SOCKET 462 SOCKET 462 AMD Take notice of the red circles as shown below While inserting the CPU into the socket you can find out there is a definite pin orientation for CPU...

Страница 17: ...nitions 2 5V DRAM Key Position Voltage Key Position 2 5V 2 2 Memory Installation Removing DIMM Press down the holding clips on both sides of a DIMM slot and the module will be released from it Make su...

Страница 18: ...AME MIDI PORT MIC LINE OUT LINE IN SW1 ON DIP 1 2 3 4 5 FLASH BIOS LPC I O Controller AC 97 Codec WOL1 1 3 AGP 4X Clock Generator 1 3 JBAT1 1 3 JP22 NJP1 SAPK RST PLED KEYLOCK SLED HDD LED IR PWR SMI...

Страница 19: ...AGP slot supports both 4X and 2X AGP cards An AGP 4X card will support a double transfer rate of an AGP 2X card When AGP 4X card is used on board it runs with 1 5V voltage In case of overclocking the...

Страница 20: ...JCD_IN1 1 4 CN1 JP3 JP4 RT2 ZD1 SSF1 30 ON DIP 1 2 3 4 5 6 SW2 1 3 JP24 To install HDD Hard Disk Drive you may connect the cable s blue connector to the mainboard s primary IDE1 or secondary IDE2 con...

Страница 21: ...O Controller AC 97 Codec WOL1 1 3 AGP 4X Clock Generator 1 3 JBAT1 1 3 JP22 NJP1 SAPK RST PLED KEYLOCK SLED HDD LED IR PWR SMI 1 JP1 JP2 SCR1 USB 3 1 1 10 14 JCD_IN1 1 4 CN1 JP3 JP4 RT2 ZD1 SSF1 30 ON...

Страница 22: ...XXXXX XXXXXXXXXXX XXXX AMD XXXX A 0850 0850 A P T 3 B T 3 B Speed 0850 850MHz 0900 900MHz 1000 1000MHz 1100 1100MHz etc Package Type M Card Module A PGA Operating Voltage S 1 5V U 1 6V P 1 7V M 1 75V...

Страница 23: ...CPGA Operating Voltage M 1 75V N 1 8V Case Temperature T 900 C S 950 C Size of L2 Cache 1 64Kbyte 3 256Kbyte Max FSB B 200MHz C 266MHz Family Architecture A AMD Athlon XP Processor Model 6 Architectur...

Страница 24: ...0 MHz 2000 at 1667 MHz TBA 1800 MHz TBA 1867 MHz TBA 2000 MHz 3 Package Type D OPGA 4 Operating Voltage K 1 65V 5 Die Temperature Q 100 0 C S 95 0 C T 90 0 C 6 Size of L2 Cache 3 256Kbyte 7 Max FSB C...

Страница 25: ...s Ratio can not be selected When DIP5 of SW1 is on LED SSF1 will be on and light is on it means that Bus Ratio Select Function is enabled As long as your CPU supports Bus Ratio Select function then Bu...

Страница 26: ...em Incorrect CPU external frequency or overclocking might cause unstable performance so we strongly recommend to leave SW2 at default setting or legal operation 33 3MHz 200MHz SW2 CPU EXTERNAL CLOCK P...

Страница 27: ...nd settings of jumper blocks on the mainboard How to tackle with Jumpers Do not remove the jumper when power is on Always make sure the power is off before changing any jumper settings Otherwise mainb...

Страница 28: ...Memory Module Voltage Select This function allows you to select the voltage supplied to the DRAM The default voltage 2 5V should be used unless processor overclocking requires a higher voltage 2 6 1...

Страница 29: ...ted by this function Setting JP24 at 1 2 closed the default setting will shut down the system when CPU gets to 85 C the default protection temperature Only when it gets cooler can you restart your sys...

Страница 30: ...MOS by 2 3 pin closed when the system is POWER OFF Then return to 1 2 pin closed position default You may damage the mainboard if clearing the CMOS with POWER ON Unplugging the power cord from power s...

Страница 31: ...s support CPU System chassis cooling fan with 12V When connecting wire to FAN connectors users should pay attention that the red wire is for the positive current and should be connected to pin 12V and...

Страница 32: ...T1 COM1 COM2 GAME MIDI PORT MIC LINE OUT LINE IN SW1 ON DIP 1 2 3 4 5 FLASH BIOS LPC I O Controller AC 97 Codec WOL1 1 3 AGP 4X Clock Generator 1 3 JBAT1 1 3 JP22 NJP1 SAPK RST PLED KEYLOCK SLED HDD L...

Страница 33: ...1 RT2 Thermal Sensor Connector Option 1 Connector RT1 A blue thermal resistor is already soldered to connector RT1 to detect the temperature round the mainboard What RT1 does is to transmit the therma...

Страница 34: ...ector Connection Connected to Connector IR on board Function Supporting wireless transmitting and receiving module on board 4 1st HDD LED Connector 2nd HDD LED Connector Connection Connected to HDD LE...

Страница 35: ...wer if the power supply does not support the load For Wake On LAN function the power supply should support at least 720mA current VCC VCC 5V GND GND GND Power Supply on GND 12V VCC3 12V 5V Standby Pow...

Страница 36: ...2 KEYBOARD PORT F USB 1 PORT G COM 1 PORT H COM 2 PORT I LINE OUT SPEAKER OUT PORT J LINE IN K MICROPHONE PIN 6 None PIN 5 Mouse Clock PIN 4 Vcc PIN 3 GND PIN 2 None PIN 1 Mouse Data PS 2 MOUSE PIN 6...

Страница 37: ...ntroller AC 97 Codec WOL1 1 3 AGP 4X Clock Generator 1 3 JBAT1 1 3 JP22 NJP1 SAPK RST PLED KEYLOCK SLED HDD LED IR PWR SMI 1 JP1 JP2 SCR1 USB 3 1 1 10 14 JCD_IN1 1 4 CN1 JP3 JP4 RT2 ZD1 SSF1 30 ON DIP...

Страница 38: ...ck Generator 1 3 JBAT1 1 3 JP22 NJP1 SAPK RST PLED KEYLOCK SLED HDD LED IR PWR SMI 1 JP1 JP2 SCR1 USB 3 1 1 10 14 JCD_IN1 1 4 CN1 JP3 JP4 RT2 ZD1 SSF1 30 ON DIP 1 2 3 4 5 6 SW2 1 3 JP24 2 7 10 Communi...

Страница 39: ...O Controller AC 97 Codec WOL1 1 3 AGP 4X Clock Generator 1 3 JBAT1 1 3 JP22 NJP1 SAPK RST PLED KEYLOCK SLED HDD LED IR PWR SMI 1 JP1 JP2 SCR1 USB 3 1 1 10 14 JCD_IN1 1 4 CN1 JP3 JP4 RT2 ZD1 SSF1 30 O...

Страница 40: ...40 75DRV5 MEMO MEMO...

Страница 41: ...ed to take the following installation orders Drivers Utilities and Software Installation Support CD This series of mainboards will always be shipped with a Support CD which contains those necessary dr...

Страница 42: ...Install Acrobat Reader Browse CD ROM Exit 2 In case your system does not open the Support CD automatically please click to the following path to enter the Main Installation Menu D Autorun exe assuming...

Страница 43: ...h e V I A S e r v i c e P a c k InstallShield Wizard will pop up to guide you to the VIA Service pack installation Press Next button to continue Next Yes VIA ATAPI Vendor Support Driver AGP VxD Drive...

Страница 44: ...Next Next 8 Select Install VIA AGP VxD in turbo mode and press Next button to continue Next Next 9 Select Install VIA IRQ Routing Miniport Driver checkbox then click the Next button to continue 10 Af...

Страница 45: ...ith your CD ROM to enter the Main Installation Menu Then click to Install VIAAC 97 Audio Driver 4 After all these setup procedures have completed click to Finish button to exit the Installation progra...

Страница 46: ...ase click to the Install Hardware Monitor Instantly a message shows up to inform you of the correct path of installing Hardware Monitor Please Exit the message and follow the path as instructed For us...

Страница 47: ...in your program file and the following screen of Smartguardian Control Panel will show up displaying the information about system temperatures voltages and Fan speed Clicking to the Option menu of the...

Страница 48: ...75DRV5 48 MEMO MEMO...

Страница 49: ...chip on the mainboard BIOS is the first program to run when you turn on your computer BIOS performs the following functions 1 Initializing and testing hardware in your computer a process called POST f...

Страница 50: ...SETUP 4 3 What Is CMOS CMOS is the memory maintained by a battery The BIOS uses CMOS to store the settings you have selected in SETUP The CMOS also maintains the internal clock Every time you turn on...

Страница 51: ...ity that updates the BIOS by uploading a new BIOS file to the programmable flash ROM on the mainboard This program only works in DOS environment only the utility can not be executed in win95 98 ME NT...

Страница 52: ...ning If the message Write Fail appears while Award FLASH MEMORY WRITER is verifying Flash memory just repeat the process Please DO NOT reset or turn off the system If the award memory flash utility is...

Страница 53: ...Chapter 4 BIOS Setup 53 Award Flash Memory Writer Start Screen Award Flash Memory Writer Complete Screen...

Страница 54: ...ar CMOS data and update data automatically after programming NOTE Users can type AWDFLASH to get further details about the parameters Incorrect usage of the parameter will damage the BIOS information...

Страница 55: ...options installed in your system 4 You may return to the Main Menu anytime by pressing ESC 5 In the Main Menu SAVE AND EXIT SETUP saves your changes and reboots the system and EXIT WITHOUT SAVING igno...

Страница 56: ...one of the arrow keys to move between options and modify the selected options by using PgUp PgDn keys 4 6 2 Standard CMOS Setup Date mm dd yy L Mon January 22 2002 Time hh mm ss L 9 52 15 IDE Primary...

Страница 57: ...e mm dd yy The BIOS determines the day of the week from the other date information This field is for information only Press the left or right arrow key to move to the desired field date month year Pre...

Страница 58: ...system memory capacity Drive A Drive B Select this field to the type s of floppy disk drive s installed in your system The choices are 360KB 5 25in 1 2MB 5 25in 720KB 3 5in 1 44MB 3 5in 2 88MB 3 5in...

Страница 59: ...ce Second Boot Device Third Boot Device Boot Other Device Swap Floppy Drive Boot Up Floppy Seek Boot Up NumLock Status Gate A20 Option Typematic Rate Setting Typematic Rate Chars Sec Typematic Delay M...

Страница 60: ...nal memory that is much faster than conventional DRAM system memory CPUs from 486 type up contain internal cache memory and most but not all modern PCs have additional external cache memory When the C...

Страница 61: ...drives to determine whether they have 40 or 80 tracks Only 360 KB floppy drives have 40 tracks drives with 270KB 1 2MB and 1 44MB capacity all have 80 tracks Because very few modern PCs have 40 track...

Страница 62: ...or 30 characters per second OS Select For DRAM 64MB Select OS2 only if you are running OS 2 operating system with greater than 64MB of RAM on your system Security Option If you have set a password sel...

Страница 63: ...h item F5 Get the previous values These values are the values with which the user starts the current session F6 Load all options with the BIOS default values F7 Load all options with the Setup default...

Страница 64: ...the memory modules BIOS reads information coded in SPD during system boot up Current FSB Frequency Current DRAM Frequency DRAM Clock DRAM Timing DRAM CAS Latency Bank Interleave DRAM Burst Length DRAM...

Страница 65: ...rst Length for DRAM Bursting feature is a technique that DRAM itself predicts the address of the next memory location to be accessed after the first address is accessed To use the feature you need to...

Страница 66: ...select AGP Mode The choice 1x 2x 4x AGP Aperture Size Series of options are available 4 8 16 32 64 128 or 256 MB Memory mapped and graphics data structures can reside in a Graphics Aperture This area...

Страница 67: ...Master 0 WS Writer PCI2 Master 0 WS Write PCI1 Post Write PCI2 Post Write Item Help Menu Level CMOS Setup Utility Copyright C 1984 2002 Award Software CPU PCI Bus Control Move Enter Select PU PD Value...

Страница 68: ...m performance Video RAM Cacheable Selecting Enabled allows caching of the video memory RAM at A0000h AFFFFh resulting in better video performance However check your AGP manual to find out if any compa...

Страница 69: ...previous values These values are the values with which the user starts the current session F6 Load all options with the BIOS default values F7 Load all options with the Setup default values 4 6 5 Int...

Страница 70: ...rface The choices Enabled Disabled VIA OnChip IDE Device IDE Prefetch Mode The on board IDE drive supports IDE perfecting for faster drive accesses If the IDE device doesn t support perfecting set thi...

Страница 71: ...ct Disabled to use the on chip audio capability of your system Most of the field do not appear when this fieldis Disabled foruserwhowantstouseadd onsound card this tiled must be disabled VIA 3068 MC97...

Страница 72: ...lect Enabled if your system has a floppy drive controller FDC installing in the system board and you want to use it If you install add in FDC or the system has no floppy drive select Disabled in this...

Страница 73: ...parallel port controller I O address setting The choices 378H IRQ7 278H IRQ5 3BC IRQ7 Disabled UR2 Duplex Mode This item allows you to select the IR half full duplex function The choices Half Full Mi...

Страница 74: ...ost new drives do select Enabled for automatic detection of the optimal number of block read write per sector the drive can support The choices Enabled Disabled USB Keyboard Support Select Enabled if...

Страница 75: ...er starts the current session F6 Load all options with the BIOS default values F7 Load all options with the Setup default values 4 6 6 Power Management Setup ACPI Function ACPI Suspend Type Power Mana...

Страница 76: ...support ACPI Suspend Mode After the selected period of system inactivity the chipset enters a hardware suspend mode stopping the CPU clock and possibly causing other system devices to enter power mana...

Страница 77: ...monitor is blanked V H SYNC Blank DPMS Supports Blank Screen This selection will cause the system to turn off the vertical and horizontal synchronization ports and write blanks to the video buffer Thi...

Страница 78: ...USB Resume from S3 This item will enable you to wake up the system by USB keyboard when you shut down the computer in S3 mode The choices Enabled Disabled Item Help Menu Level Move Enter Select PU PD...

Страница 79: ...waken the system This option is concurrent with Resume Time option Resume Time hh mm ss Set a certain time when RTC Alarm Resume option is Enabled to awaken the system This option is concurrent with D...

Страница 80: ...ware IRQ Activity Monitoring Move Enter Select PU PD Value F10 Save ESC Exit F1 General Help F5 Previous Values F6 Fail Safe Defaults F7 Optimized Defaults ON Enabled Enabled Enabled Enabled Enabled D...

Страница 81: ...e user starts the current session F6 Load all options with the BIOS default values F7 Load all options with the Setup default values 4 6 7 PnP PCI Configuration PNP OS Installed Reset Configuration Da...

Страница 82: ...o modify the information delivered from the feature Connector of the VGA card to MPEG card This option can solve the display inversion to black after you have used MPEG card Assign IRQ for USB Select...

Страница 83: ...Please refer to the list below IRQ 3 assigned to PCI ISA PnP IRQ 4 assigned to PCI ISA PnP IRQ 5 assigned to PCI ISA PnP IRQ 7 assigned to PCI ISA PnP IRQ 9 assigned to PCI ISA PnP IRQ 10 assigned to...

Страница 84: ...able for each item F5 Get the previous values These values are the values with which the user starts the current session F6 Load all options with the BIOS default values F7 Load all options with the S...

Страница 85: ...Warning Speed This feature prevents the malfunction of the CPU cooling fan When CPU cooling fan speed is lower than value you select in this field the BIOS will send out sequence of beeps or send out...

Страница 86: ...inish setting up all items FAN 1 3 Speed These fields display the current speed of up to twoCPU fans if your computer contains a monitoring system Temperature 1 2 3 This field displays the current CPU...

Страница 87: ...n F6 Load all options with the BIOS default values F7 Load all options with the Setup default values 4 6 9 Frequency Voltage Control Red Storm Overclocking CPU Vcore Select Auto Detect DIMM PCI ClK Sp...

Страница 88: ...understand it CHIP Skew Adjust Leave this field at default AGP Skew Adjust Leave this field at default PCI Skew Adjust Leave this field at default Use CPU Linear Freq If users would like to adjust CPU...

Страница 89: ...ed characters 3 After you enter the password the following message appears prompting you to confirm the password Confirm Password 4 Enter the same password exactly the same as you have just typed to c...

Страница 90: ...EXIT Y N Y Y is for Yes and N is for No Press Enter key to save the configuration changes 4 6 13 Exit Without Saving EXIT WITHOUT SAVING option allows you to exit the Setup Utility without saving the...

Страница 91: ...Chapter 4 BIOS Setup 91 MEMO MEMO...

Страница 92: ...APPENDIX 92 Appendices APPENDIX 1 Identify BIOS Version BIOS Part Number APPENDIX 2 Identify Mainboard Model Number APPENDIX 3 Technical Terms...

Страница 93: ...93 See Picture 1 below for BIOS version and BIOS part number identification Picture 1 1 2 1 BIOS VERSION example REV T2 1 2 BIOS ID STRING example 6A69RSNCC Appendix 1 Identify BIOS Version BIOS Part...

Страница 94: ...Number Usually the mainboard model number is labeled on the side of ISA side of slot or PCI slot Please see the picture below as an illustration 2 1 1 MAINBOARD MODEL NUMBER example SL 65KV2 2 MAINBO...

Страница 95: ...ta transfer rate is 66MHz x 4byte x 2 528MB s AGP 4X mode is 66MHz x 4byte x 4 1056MB s AMR Audio Modem Riser AMR is an interface to connect the CODEC circuit of AC 97 sound modem solution to the main...

Страница 96: ...master IDE device transfers data from to memory without interrupting CPU and releases CPU to operate concurrently while data is transferring between memory and IDE device You need the bus master IDE d...

Страница 97: ...or parallel ports EPP Enhanced Parallel Port EPP is a standard that supports data transfer rates of up to 500 kps for parallel printers EDO Extended Data Output Memory Unlike traditional FPM Fast Page...

Страница 98: ...EEE 1394 is a low cost digital transfer interface with transfer rate at 100 200 or 400 Mbps It provides solutions of connecting digital television devices and Serial Bus Management There are two type...

Страница 99: ...tomatically allocate the IRQ DMA Memory Currently almost all the PCI cards and most ISA cards are already PnP compliant POST Power On Self Test The BIOS self test procedure after power on It is genera...

Страница 100: ...o SPD so that BIOS can access it and use it to decide best timing for this DIMM or RIMM UART Universal Asynchronous Receiver transmitter UART is built in a chip that controls the data send and receive...

Страница 101: ...tage regulator Module This is a small module installed on a mainboard to regulate the voltage fed into the processor on board Voltage regulator can be built on board in various way VRM is a socketed t...

Страница 102: ...APPENDIX 102 MEMO MEMO...

Отзывы: