 Remote Control Guide

16ft–33ft

The range of the remote control to the 
indicator is 16ft (Day time) to 33ft (Night 
time). Because the sunlight will impact  
the signal of the remote control, we recom-
mend that users setup the mode before  
they install the light. 

1. On/Off

When off is selected, the light will stop working. The solar panel will not 
charge the battery and the battery will not supply electricity to the light. 

2. Connect/Test

Remote control device can be connected with any lighting fixture, one 
at a time. To connect, press the button once. It also functions as a test 
button. To test, press the “Test” button once, the red light will indicate 
the fixture is charging, green light indicates that the fixture is operating. 
Testing lasts for 10 seconds, and then it goes back to the mode previously  
in use. 

 

1.

 On/Off

2.

 Connect/Test

4.

 20%~80% Motion  

     Sensor Mode (Default)

6.

 Early Bird Mode 

8.

 70% Constant Mode

10.

 Timer Mode Disabled

12.

 Time Mode 8 Hours 

 

3.

 40%~100% Motion 

Sensor Mode 

 

5.

 Night Owl Mode 

 

7.

 100% Constant Mode 

9.

 40% Constant Mode 

11. 

Timer Mode 4 Hours 

Содержание CEGONIA 8W

Страница 1: ...01 CEGONIA 8W 20W 30W Installation Manual SOLTECH Designs and Manufactures Advanced Solar Powered LED Technology ...

Страница 2: ...02 CEGONIA 8W CEGONIA 20W CEGONIA 30W ...

Страница 3: ...Introduction 02 Luminous Distribution 03 Battery Notes 04 Installation and Wiring Compliance 05 Mounting Accessories 06 Installation 07 Panel Angle 08 Remote Control Guide Contents 04 06 07 08 09 010 012 014 ...

Страница 4: ...Read all of the instructions carefully before attempting to carry out any installation or wiring Do not open or attempt to repair the product on your own as it many cause serious damage and would void the product warranty Contact your local distributor for any questions concerning the installation Range of the light module on the lighting fixture is 20 26 feet 6 8 meters The ideal installation spa...

Страница 5: ... 8 inches 6 0 inches CEGONIA 20W SOLAR PANEL 8 2 Lbs SOLAR LAMP 12 1 Lbs BATTERY ASSEMBLY 14 3 Lbs 11 0 inches 24 0 inches 1 2 inches 9 5 inches 20 1 inches 30 4 inches 8 5 inches CEGONIA 30W SOLAR PANEL 9 9 Lbs SOLAR LAMP 13 6 Lbs BATTERY ASSEMBLY 16 9 Lbs 31 0 inches 11 0 inches 1 2 inches 9 5 inches 20 1 inches 30 4 inches 8 5 inches ...

Страница 6: ...06 02 Luminous Distribution CEGONIA 8W Type III CEGONIA 20W Type III CEGONIA 30W Type III ...

Страница 7: ...charger to charge reset the switch when done Battery Replacement 1 Disconnect the wire connectors 2 Loose the screws of the battey pack and take out the battey pack 3 Replace a new one 4 Tighten the screws of battery pack 5 Connect the wire connectors Be sure you match the color when you connect them IAP Intelligent Adaptive Program Battery Control Technology In order to extend the off grid autono...

Страница 8: ...if applicable please ensure the light pole and its foundation are solid enough to withstand the lighting fixture s 5 Before installation please ensure that the battery is fully charged Install during sunny days if possible 6 Before installation please press the ON OFF key in the remote control and check whether it shows a red light on the indicator Please cover the panel and check if the light mod...

Страница 9: ...s poles C b TLSTC 20W 30W TRS for CEGONIA 20W 30W works with 2 0 inches to 4 0 inches poles Pole Size 2 0 inches 4 0 inches B a STLSTE 8W TRR for CEGONIA 8W works with 2 4 inches to 4 0 inches poles Pole Size 2 4 inches 4 0 inches Pole Size 2 4 inches 4 0 inches C a STLSTC 8W TRS for CEGONIA 8W works with 2 0 inches to 4 0 inches poles Pole Size 2 0 inches 4 0 inches 0 5 inches 0 2 inches 5 1 inch...

Страница 10: ...IA 8W Component Kit B Component Kit A Loose screws of component kit B to adjust the angle of solar panel Loose screws of component kit A to rotate solar panel 180 45 Connect Connect Connect Connect Connect Connect 180 45 180 45 ...

Страница 11: ...Component Kit B Loose screws of component kit B to adjust the angle of solar panel Loose screws of component kit A to rotate solar panel 45 270 CEGONIA 20W 30W Connect Connect 45 45 270 270 Connect Connect Connect Connect ...

Страница 12: ...5 N 36 N 37 N 38 N 39 N 40 N 41 N 42 N 43 N 44 N 45 N 46 N 47 N 48 N 60 N 49 N Washington Oregon California Nevada Arizona Utah New Mexico Kansas Colorado Oklahoma Texas North Dakota South Dakota Nebraska Idaho Montana Wyoming 61 N 62 N 63 N 64 N 65 N 70 N 66 N 67 N 68 N 69 N Hawaii Minne I ...

Страница 13: ...irginia West Virginia Kentucky Illinois Wisconsin esota Iowa Missouri Michigan Indiana Ohio Pennsylvania New York Massachusetts Rhode Island Connecticut New Jersey Delaware Maryland Tennessee Florida World Wide Panel Angles New Hampshire Vermont Maine 30 30 07 Panel Angle Best Facing Direction For The Solar Panel Worst Best OK OK The area will dictate the installation of the fixtures and will some...

Страница 14: ...nnect Test Remote control device can be connected with any lighting fixture one at a time To connect press the button once It also functions as a test button To test press the Test button once the red light will indicate the fixture is charging green light indicates that the fixture is operating Testing lasts for 10 seconds and then it goes back to the mode previously in use 1 On Off 2 Connect Tes...

Страница 15: ... capac ity and adjust light output accordingly Prior to including this feature selecting a light output percentage on the remote determined the constant percentage of max LED brightness Now with IAP the controller actively monitors the battery and regulates the electrical current to the LEDs The controller now applies the selected percentage output on the remote to the battery capacity rather than...

Страница 16: ...ghtness from dusk to dawn 9 40 Constant Mode 40 brightness from dusk to dawn 10 Timer Mode Disabled Press this button to turn off Timer Mode settings revert back to before Timer Mode was last activated 7 100 Constant Mode 100 brightness from dusk to dawn ...

Страница 17: ...an additional mode which can work with any other modes For example press this button at any time after you turn on 70 Con stant Mode If the light turns on at 7pm at dusk it will turn off at 3am It will repeat the same schedule hereafter until it is canceled by pressing Timer Mode Disabled Important Dusk and dawn time can vary for different locations and seasons The sensors in our products will mon...

Страница 18: ...ights Reserved CEGONIA products are covered by a 5 year limited warranty SOLTECH urban light warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 5 years from date of purchase To obtain warranty service please contact your local distributor or sales rep for further instruction 1460 Park Avenue Emeryville CA 94608 USA www soltechli...

Страница 19: ...019 ...

Страница 20: ...020 SOLTECH Designs and Manufactures Advanced Solar Powered LED Technology ...

Отзывы: