Soltec Pergola Agava SL 160/28 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Februar, 2018 

 

 

        Installation instructions  1.1 
 

Pergola Agava SL 160/28 , 170/28 , 170/36 

Self standing

  

 

 

Содержание Pergola Agava SL 160/28

Страница 1: ...1 Februar 2018 Installation instructions 1 1 Pergola Agava SL 160 28 170 28 170 36 Self standing ...

Страница 2: ...2 ...

Страница 3: ...ing longitudinal frame profiles with upper L angle 14 Step 7 Position of foot support 15 Step 8 Attachment of pedestals 16 Step 9 Laying frames on posts 17 Step 10 Screwing the posts and foot support 18 Step 11 Assembly of blades 19 Step 12 Connection of blades and drive batten 21 C REMOTE CONTROL SETTINGS AND MANAGEMENT 22 D OPTIONS 24 Sliding glass panel 24 Sliding panel aluminum wooden battens ...

Страница 4: ...4 A TOOLS EQUIPMENT 8 6 Ø10 10 13 17 Ø12 ...

Страница 5: ...el Step 1 Check goods receive BEFORE you begin installation CHECK 1 The amount of pieces in the received assembly 2 The quality of the pieces in the received assembly 3 Installation instructions 4 Maintenance instructions 5 Warranty statement ...

Страница 6: ...tanding model W width of Pergola L length of Pergola H height of Pergola L1 longitudinal frame profile with motor unit and holes for blades L2 longitudinal frame profile with holes for blades W1 transverse frame profile with electronic no holes for blades W2 transverse frame profile no holes for blades INSTRUCTIONS L W H L1 W1 W2 L2 ...

Страница 7: ...7 Step 3 Required space Put four pedestals on a suitable place big enough for assembling Pedestals MUST be coated to avoid damage on frames P1 P3 P4 P2 ...

Страница 8: ...ewing the upper L angle into transverse frame profiles Insert upper L angle AA into transverse frame profiles W1 W2 Screw upper L angle and the profile with screws A Repeat the same in positions P2 P3 P4 AA A P1 P1 ...

Страница 9: ...angle AB into transverse frame profile The screw C is screwed into the M6 hole Repeat the same in positions P2 P3 P4 Insert lower L angles into the corresponding places in other transverse frame profile AB P1 P1 P2 P3 P4 C ...

Страница 10: ...n the frames are not screwed together Blades motor unit and LED lights are preset in the factory ZIP rolo is not preset in the factory Preset of the ZIP rolo should be done by installer After completing the installation the metal constructions must be grounded Connecting cables Position 1 Cable for drive unit è plug and socket AG Cables for LED lights on the bladesèplug and socket AF Cable for ZIP...

Страница 11: ...perly connected if the inscription ALTW on the connectors is visible on the same side LED light position 2 Connect plug and socket on AF joint ZIP rolo position 1 if ordered Connect plug and socket on AH joint Wires of the same colors are connected to each other AF AF AH ALTW ...

Страница 12: ...rted into a longitudinal profile Caution the cables in profiles must not be damaged 2 Connection to electrical voltage When the frame is assembled the power cord 3 2 5 mm2 is connected to the electrical voltage Only a trained person can carry out the connection N neutral L phase G ground 220V N L G P1 P2 P3 P4 W1 W2 ...

Страница 13: ... a vertical position 4 Testing LED lights Use the remote control and follow the instructions chapter C Check if all LEDs are ON and OFF When testing is complete disconnect the connectors AF BB Blades with LED lights 5 Testing ZIP rolo if ordered Check the rolo movement up and down The final setting is done when the frame is set on location Use remote control follow instruction in chapter C AF AF A...

Страница 14: ...ing you must disconnect the power supply Step 6 Screwing longitudinal frame profiles with upper L angle Through openings on longitudinal frame profiles a profile and a upper L angle are screwed Repeat at position P2 P3 P4 A P1 ...

Страница 15: ... T3 T4 Position of foundations under posts Warning X1 X2 Use a laser gauge The foot support must be at the same height H1 H2 H3 H4 or the height must be adapted to the situation on the ground Use a laser gauge T2 T1 T4 90 90 90 90 X1 X2 H1 H2 H4 0 AE LASER W L ...

Страница 16: ... into the foundation Use a drill for concrete with a diameter of 12 mm Screw is inserted into the foundation The position of the support steel foots before mounting the posts The diagonal pair of support steel foots must be mutually parallel P1ǁP4 and P2ǁP3 Ø12 E W L P1 P2 P3 P4 ...

Страница 17: ...ent It is necessary to pay attention to the correct position and orientation of the posts Check your plans and your order Use the screws B and screw the lower L angle with posts It is necessary to have a hexagonal key which has to be long at least 20 cm Openings on the upper side of the frame seal with plastic bushes P The bonding edges seal with adhesive P3 min 20cm P B ...

Страница 18: ...of the holes The position of the hole is adjusted to the conditions at the installation site Check the position of the hole M8 on the foot support 1 2 Two holes with a diameter of 10 mm must be drilled into the post P on the two parallel sides 3 After the drill is done screw D is screwing to fix post and foot support Ø10 AE P 1 2 3 ...

Страница 19: ... a composite and standing frame First insert the blades at both ends The long axis of the blade is inserted into the profile with motor drive The long axis of the blade is on the side of the blade where the cover is located which is screwed onto the drive batten 1 1 P1 P2 P3 P4 ...

Страница 20: ...is are inserted into the frame Place a distance plastic bush N around the longer kingpin J After installing the distance plastic bush move the blade in the direction of the longer axis On the side of the shorter axis there should be a space of 3 4 mm between the blade and the frame Direction of movement N J Direction of movement 3 4 mm Drive unit K Drive unit Drive unit N ...

Страница 21: ... the blade cover and the drive batten and fasten it with L screw Continue with connection of remaining blades by fastening L screws by hand NOT by electrical screw driver Adjustment of closing of the blades 1 When you fix screws make a self test on Teleco driver 2 On the side where the blades are still open unscrew the blades Move the inox profile 1mm from the center toward the corner of the pergo...

Страница 22: ...rted into their axis Number of those blades depend on the lenght of L1 L2 profiles Positions of these blades are determined by service holes 1 on the top of the longitudinal frame profile C REMOTE CONTROL SETTINGS AND MANAGEMENT DANGER Hazard of crushing hands or limbs 4m L1 L2 1 ...

Страница 23: ...23 DANGER Hazard of crushing hands or limbs ...

Страница 24: ...24 D OPTIONS Sliding glass panel ...

Страница 25: ...l 10mm tempered glass KP Panel profile KC Panel Cover KO Bootom wheel 1 Panel profiles KP are fitted on the glass KG 2 Panel covers KC are fixed to the bootom panel profiles KS Two wheels KO are fixed to bootom panel profile KG KP KC 2 1 KO ...

Страница 26: ...KB 122 dimension for glass profile for four glasses Screw for concrete with ply apropriate diameter and length The surface on which the screw profile has to be smooth without irregularities and horizontal Installation of the lock system 5 The locks KL are fixed by screws to the opposite ends of upper and bootom profile KU KB KO 5 KL 3 50 40 81 122 23 81 122 18 18 10 d 6mm L 60 80mm 4 ...

Страница 27: ... the wheel and the panel With nuts on the screw adjust the height of the panel Sliding panel hangs on the upper track and moves it Place the bottom guide 6 under the sliding panel so that the bottom profile 4B of the panel is just above the guide Screw the bottom guide into the base 7 Use a suitable screw with respect to the ground concrete wood ceramic tiles 3S Sliding panel leveling screw 5 Fill...

Страница 28: ...r mechanism 1 is attached to the frame profile 2 Guides of the rolo 3 left and right must be fastened on the posts 4 Use self tapping screw The outer side of the column and the outer side of the guide must be in the same plane 1 2 3 3 4 ...

Страница 29: ...urface that is completely exposed to rain For example the upper surface of the frame for the blades Signal cable in the sensor 3 is connected to the control unit 4 located in the W profile Wires in the cable must be connected at the appropriate coupling points White wire 12V çè 9 Blue wire signal çè10 Yellow wire ground çè 11 1 2 3 4 ...

Страница 30: ... Sensor is mounted on a verticale surface The location of the accommodation must not be in the shelter Signal cable in the sensor 3 is connected to the control unit 4 located in the W profile Wires in the cable must be connected at the appropriate coupling points Blue wire çè7 Braun wire çè 8 1 2 3 4 ...

Страница 31: ...ed into the profile from the frame The location of the accommodation must not be in the shelter The sensor is designed to alert you to low temperatures Signal cable in the sensor 1 is connected to the control unit 2 located in the W profile Wires in the cable must be connected at the appropriate coupling points Black wire çè14 White wire çè 15 1 2 ...

Страница 32: ...with connectors AG AF AH plastic bushes 1 L1 Longitudinal frame profile without motor and with holes for blades length L with components cover plates for service holes for connecting rods with screws M5 x 12 plastic bushes 1 L2 Transverse profile of the frame with service hole length W with components control unit for motor cover plate with screws M5 x 12 cables with connectors AG AF AH transforma...

Страница 33: ...rofile lower 4 AB U support steel foot 4 AE Optional foot mounting Screw with hexagon round head with collar inox M10 x 20 24 D Screw with hexagon socket head inox M10 x 30 16 B Anchor bolt galvanized M12 x 135 8 E Screw with hexagon round head with collar inox M6 x 16 8 C Blade with components kingpin long and short blade covers sealing rubber n1 ...

Страница 34: ... short with holes for rod blade covers sealing rubber connecting rod 2 nuts M6 self locking hex 2 washers M6 large flat n3 Distance plastic bush n n1 n2 n3 n N Plastic cap for holes on upper side of the frame Ø18 16 P GLASS PANEL Panel profile for glass s number of temperet glasses s KP Panel cover for glass 2 s KC Bottom profile for glass panel 2 s KO Upper profile for glass panel 1 KU Bottom whe...

Страница 35: ... Scandinavia Andrea Girelli Via cormor alto 179 I 33100 Udine E andrea girelli soltec si M 386 0 40 809 881 Slovenia Croatia Belgium Dutch Peter Kovačič Obrtna ulica 9 SI 8257 Dobova E peter kovacic soltec si M 386 0 40 851 600 Germany Austria Switzerland Carmen Hostnik Obrtna ulica 9 SI 8257 Dobova E backoffice soltec si M 386 0 40 656 941 T 386 0 7 62 00 424 13 ...

Страница 36: ...36 ...

Отзывы: