CSW-H80 User Manual Ver. 3.0
- 40 -
5.4
UDP
UDP has no processes of connection. In this mode, data is sent by block unit. Therefore,
data coming through CSW-H80’s serial port is classified by block units to send it elsewhere.
Block Size(Byte)
[Block Size(Byte)] is the size of a block in UDP mode. Its unit is byte. If the data in
configured size of the [Block Size(Byte)] has come into the serial port, CSW-H80
sends them as one block to the network. The maximum value could be 1460 bytes.
Data Frame
[Data Frame] is the time to gather data to for one block. Its unit is 10ms. If there are
no data from the serial devices during the [Data Frame] time, CSW-H80 sends and
receives data in the buffer as one block to the network.
Once one of the two parameters is sufficient, event byte and data frame, UDP
packet block will be transmitted.
Dynamic update of Peer host
If users set the value of [Peer Address] and [Peer Port] to 0, [dynamic update of peer
host] function is activated. By using this function, CSW-H80 can communicate to
multiple hosts without additional setting.