CIE-M10 User’s Manual Ver. 1.1
Sollae Systems Co., Ltd.
- 25 -
http://www. eztcp.com
6
Operation
6.1
Operation Mode
The following is a table of CIE-M10‟s operation mode.
Mode
How to enter
Function
Baudrate
Normal
ISP-: High or Open when it boots up
Normal
User defined
Serial
Configura
tion
ISP- Low for 20ms~1,000ms in the
Normal Mode
Configuring the
CIE-M10 through
serial port
115,200bps-
None-8-1
ISP
1. ISP- Low when it boots up
2. ISP- Low more than 1 second
Uploading new
firmware
and
user‟s web page
–
Table 6-1 ezTCP Operation Mode
6.1.1
Normal Mode
CIE-M10 operates normally in this mode.
If a CIE-M10‟s ISP- pin is high or open, it operates as Normal Mode.
Please refer to “7. Input / Output Ports” and “8. Serial Port” for more information.
6.1.2
Serial Configuration Mode
User can set CIE-M10‟s parameters through its serial port in this mode. CIE-M10 enters into the
Serial Configuration Mode by inputting low signal to the ISP- pin for 20ms ~ 1,000ms. User can
configure CIE-M10 through the serial port with the ezManager in this mode.
The yellow LED of the RJ-45 connector blinks every 0.5 second and all security functions are
disabled. So user can fix some problems because of security functions.
6.1.3
ISP Mode
User can upload new firmware and user‟s web page in the ISP mode. If the ISP pin is low when
the CIE-M10 boots up, it enters into the ISP mode. And if the ISP pin is low more than 1
second in the Normal Mode, it enters into the ISP mode as well.
6.2
Uploading New Firmware