Operating Instructions 
Dear customer, thank you for purchasing our product. Please read the following instructions carefully and 
follow them to ensure that the product serves you safely and to your full satisfaction. This will prevent 
misuse or damage. Avoid unprofessional handling of this appliance and always observe the electrical 
appliance usage guidelines. Keep the instruction manual carefully. For indoor use. This product should only 
be used by an adult. Never expose to environments with high humidity (e.g. bathroom), avoid contact of 
the product with liquids.  
 
Contents of the set 

 

1x germicidal UV lamp    

 

1x remote control 

 

1x instruction manual 

Functions 
Direct radiation lamps are used where it is possible to ensure that people are not present during 
disinfection. Disinfection with these lamps is most effective because they sterilise micro-organisms on the 
surface of objects as well as in the air and liquids. This product is used for direct and indirect disinfection of 
premises.  
Direct disinfection refers to gases, liquids and objects that are exposed to direct effective ultraviolet C 
radiation. These gases, liquids or objects must be directly exposed to UVC radiation. Effective radiation 
means the intensity of UVC radiation sufficient to inactivate viruses, moulds, bacteria or fungi.   
Indirect disinfection is carried out with O3 gas (ozone), which is produced by UVC radiation. This gas enters 
all parts of the room (even behind obstacles) and disinfects.  

 

Service 
Plug the device into a power outlet. The device has a 15/30/60min timer option. Select the length of the 
interval according to the level of disinfection required. Use the button on the lamp to select the desired 
time interval. Red light 15 min, green light 30 min, white light 60 min. Once the desired interval length has 
been selected, the countdown starts and is signalled by a beeping sound. This countdown lasts approx. 15 - 
20 sec. During this time, the electrodes of the tube are heated and then the lamp is switched on. The lamp 
will be switched off after the specified time interval or can be switched off at any time by pressing the 
button on the lamp. 
Remote control - press the red power button on the remote control. Then press the button of the 
appropriate time interval length (15min, 30min, 60min). This will cause the tube to glow, approx. 15 - 20 
sec, after which the lamp will be switched on. The lamp will be switched off after the specified time 
interval or can be switched off at any time by pressing the red power button on the remote control.  
Recommended time for disinfection: room approx. 20m2 - 15min; room approx. 30m2 - 30min; room 
approx. 40m2 - 60min. 
 
Safety instructions 
Once the lamp is switched on, neither people nor animals should be in the disinfected environment. UVC 
radiation is harmful even in small doses and may have some negative effect on humans, animals or plants. 
The intensity and duration of exposure are decisive. Do not look directly into a lit UVC lamp. Even a small 
dose of UVC radiation can cause conjunctivitis or so-called welding disease (ophthalmia photoelectrica) if 
the eye is exposed for a long time. At higher doses, UVC radiation can severely damage eyesight. The skin 
and eyes of children are particularly sensitive to the effects of UVC radiation. Children must not be exposed 
to direct radiation at all. Only reflected radiation from distant walls or ceilings is permissible for the 
shortest possible time. The room should be cleaned of dirt before disinfection begins. The room should be 
dry and the temperature between 20° and 40°C. UVC radiation can damage various paintings, pictures and 
decorations.  