E-mail send to:
Enter a valid e-mail address to receive the
alerts. The "Send Test" option sends a test email to the de-
clared address.
If you require alerts to reach more than one email ad-
dress, you can use the automatic mail forwarding ser-
vice of the email account.
The check boxes "LOG" and "E-MAIL" enable the recording
of each issue in the internal log and for sending alarms re-
spectively.
Audio silence:
Send an alert when detect a silence that ex-
ceed the limit established in seconds. The value is set us-
ing the right slider.
Overmodulation:
Sends an alert when detects that the
modulation index exceeds the value set for the alarms.
The value is set using the right slider. This value does not
affect the transmission in any way.
LOW RF power level:
Send an alert if a drop in the trans-
mitted power is detected. To set the value, press "Set REF"
under normal transmission conditions. Then using the
slider indicate the percentage of power loss for which the
alarm will be activated. This value does not interfere the
transmission in any way.
System START:
Generates an alarm in case the processor
restarts (for example due to power cut)
System Errors:
For internal use. Only system events are
logged in the SYSLOG.
3.12.2 Status and Logs
SYSTEM TIME:
When the computer is connected to a
LAN with Internet access, the computer keeps its time
synchronized using an NTP server.
SYNC FROM PC
allows synchronization against the clock
of the computer from which it is accessed.
The date and time is only used to record system events
in technical reports.
SYSLOG:
It is an event log stored into the processor’s
memory. Reserved for use by personnel specialized in di-
agnostic tasks and technical support.
3.12 Lite Commander
Lite Commander is a tool for Windows that allows
to program preset changes and switch the mode of
transmission from stereo to mono, according to a
schedule. The mono transmission option is useful
in areas of high congestion in the radio spectrum,
as it extends the coverage area of the radio. This
trick can be used in news programs or sports
broadcasts (see "3.8.3 About mono transmission").
Lite Commanrder is free download from
www.solidynepro.com/DW/lite.exe
. Installation
and use instructions are installed with the soft-
ware.
The application connects to the processor via IP,
so the computer running Lite Comander must have
access to the IP of the 542APC.
Audio Processing Core -
SOLIDYNE 542
APC
Page 29
Figure 32: Alarms settings
Содержание 542 APC
Страница 1: ......
Страница 2: ...Page 2 Audio Processing Core SOLIDYNE 542APC...
Страница 6: ...Page 6 Audio Processing Core SOLIDYNE 542APC...
Страница 10: ...Page 10 Audio Processing Core SOLIDYNE 542APC...
Страница 30: ...Page 30 Audio Processing Core SOLIDYNE 542APC...
Страница 42: ...Page 42 Audio Processing Core SOLIDYNE 542APC...