Appendix E - Selecting Mains Voltage
Fusion has a linear power supply and therefore needs to be manually switched to operate with
either a 230V or 115V power suppy. The AC mains fuse is located on the rear panel next to the AC
mains connector. The orientation of the main fuse cartridge will dictate the operational voltage; this
can be either 230V or 115V AC power.
The operational value of the fuse is displayed through a slot on the fastening that holds the fuse in
place (as shown).
Note: Only one fuse is supplied with Fusion. Each operational voltage requires a different fuse:
230V - Current Rating 500mA, Voltage Rating 250 V AC, Body Material Glass(LBC), Size 5mmx20mm
115V - Current Rating 1A, Voltage Rating 250 V AC, Body Material Glass(LBC), Size 5mmx20mm
Changing the fuse from 115V to 230V
1.
Remove the IEC power cable from the IEC socket.
2.
Remove the fastening by leveraging a flat-head screwdriver in the slot at the top of the fuse panel.
3. Remove the fuse cartridge, then remove the small metal link plate. Place the link plate on the opposite side of the fuse
cartridge (you will need to remove the fuse to do this).
4. Place the new fuse in the vacant slot on the opposite side of the fuse cartridge.
5. Re-orientate the fuse cartridge 180 degrees and reposition it so that the alternate operating voltage value is displayed
through the slot in the fastening. Re-seal the fastening, reconnect the IEC power cable, and switch the unit on.