8
The design static load on the module is 1600Pa on the back and 3600Pa on the front .The safety fac
tor is equal to 1.5.The maximum static load on the module is 2400Pa on the back (equal to wind pres
sure) and 5400Pa on the front (equal to snow pressure) .
5.2
Installation method
The connection of the module and the bracket system shall be made by using the above-mentioned
mounting connectors to form a complete system for installation. The installation component must be
based on the following example, not complying with the following installation requirements may
result in a warranty invalid.
5.2.1Install module by link channel
Please use the link channel provided by SOLGLASS, which are arranged on the roof bracket
through the slot, and then place the module on the connecting hook, each link channel is 20 cm
apart from each other, evenly arranged on the roof bracket, the top and bottom modules are aligned.
After installation, the top is fixed with the top bracket. The diagram is as follows:
Link channel