6

Consult local laws and regulations before installing modules to comply with building fire proofing
safety requirements.

Different roof structure and installation methods will affect the building's fire proofing safety
performance. If the module is not properly installed, it may cause a fire.
Use the appropriate components such as fuses, circuit breakers, and ground connectors as required
by local regulations. Do not use modules if flammable gas is present nearby.

4. installation conditions

4.1 Installation Location and working environment

The module can only be used on earth under 2000m altitude, not in space.

Modules can not be installed and used in excessive environment such as excessive salt, fog,

hail, snow, sand, smoke, air pollution, active chemical vapor, acid rain, soot, etc.

When there is heavy snow, extremely cold, strong wind or near water, close to salt fog on the

island or desert environment, please use appropriate protective measures to ensure the reliability
and safety of module installation.

Components must be installed on suitable buildings or other suitable locations (eg. Ground,

garage, building facade, roof, PV tracking system) and components can not be installed on any
type of mobile vehicle.

Do not install modules on the location where there is a risk of flooding.

It is recommended that the module is needed to be installed in a working environment with a

temperature of-40 °C to 40 °C, which is the monthly maximum and minimum temperature at the
location of the installation. The limit working environment temperature of the module is-40 °C to
85 °C.

Ensure that the wind or snow pressure on the module after installation does not exceed the

maximum allowable load.

module need to be installed in a no shaded area throughout the year.

Ensure that there are no obstructions that may block light at the location where the module is

installed.

If the module is installed in a place with frequent lightning activity, the module must be protected

against lightning strikes.

Do not install modules in a place where flammable gases may be present. The SOLGLASS’s

module shall not be installed in a place where strong corrosive substances such as salt, brine, or
any other material may corrode the modules, affecting its safety or performance.

SOLGLASS’s module have passed the salt spray corrosion test of the IEC61701, but corrosion

can occur at the edges of the components where they are connected to the bracket, or where
they are connected to the ground.

Содержание Solartrix 1200-400 Series

Страница 1: ... of the installation and safe use of information All safety aspects of this guide precautions and local regulations should be followed during modules installation and routine maintenance Precautions and local regulations Installing module system requires expertise and knowledge it can only be done by qualified personnel Please read this installation manual carefully before installing and using mod...

Страница 2: ...es SOLGLASS does not assume any relevant liability SOLGLASS reserves the right to change the product description and this installation manual without prior notice Customer doesn t comply with the requirements set out in this manual will result in the failure of the limited warranty at the time of sale At the same time the recommendations in this manual are designed to improve the security of modul...

Страница 3: ...fety precautions solar module structure and component description Solartrix 1200 400 xx 4 3 2 1 5 Mounting fitting 6 7 1 cable 2 junction 3 cells 4 solar glass 5 connector 6 connecting slot 7 connecting hook ...

Страница 4: ...ofs 3 2 Electrical Safety PV products generate direct current in the presence of sunlight so touching the the wire metal of the module can be a risk of electric shock or burn A 30 volt DC or higher voltage can be fatal The module also generates voltage without connecting the loads or external circuit Use an insulated tool and wear rubber gloves when operating module in the sunlight There s no swit...

Страница 5: ...t stack modules above the maximum stack number printed on the package Please put the packing box in a cool and dry place before unpacking the packages To open SOLGLASS s box follow its instructions In no case shall the module be lifted by holding on to the junction box or wire never stand or move on the module Never drop one module onto another In order to avoid breakage of the glass do not place ...

Страница 6: ...acking system and components can not be installed on any type of mobile vehicle Do not install modules on the location where there is a risk of flooding It is recommended that the module is needed to be installed in a working environment with a temperature of 40 C to 40 C which is the monthly maximum and minimum temperature at the location of the installation The limit working environment temperat...

Страница 7: ...ad conditions which is a guarantee that the bracket installer must provide Mounting brackets must be tested and tested by a third party tester with static mechanical analysis capability using local national or international standards or equivalent standards module mounting brackets shall be constructed of durable corrosion resistant UV resistant materials The module must be securely mounted on the...

Страница 8: ... complete system for installation The installation component must be based on the following example not complying with the following installation requirements may result in a warranty invalid 5 2 1Install module by link channel Please use the link channel provided by SOLGLASS which are arranged on the roof bracket through the slot and then place the module on the connecting hook each link channel ...

Страница 9: ...rd test conditions perhaps the value is relatively higher compare to the value obtained under component standard test conditions Therefore in the determination of photovoltaic system accessories such as rated voltage wire capacity fuse capacity and module power output and related parameters the relating short current and open voltage amplify 1 25 times can be applied ...

Страница 10: ...Short Circuit Current Isc A 1 83 5 1 87 5 Power Tolerance 3 Maximum System Voltage VDC 1000 Maximum Series Fuse Rating A 3 Operating Temperature C 40 85 Pmax Temperature Coefficient C 0 40 Voc Temperature Coefficient C 0 31 Isc Temperature Coefficient C 0 05 STC lrradiance 1000 W m2 module temperature 25 C AM 1 5 Power measurement tolerance 3 Mechanical Specifications External Dimension 1200 400 6...

Страница 11: ...when the modules are connected in parallel the final current is the sum of the individual module as shown below The modules with different electrical parameters cannot be connected in a series Series connection Paralleling connection Series and paralleling connection Diode Over current protector Connector ...

Страница 12: ...ox one positive and one negative The two modules can be connected in series by inserting a positive terminal at the other end of a module wire into the socket of the negative terminal of an adjacent component Field connection cables must meet the component s maximum short circuit current usage and SOLGLASS recommends that installers use only light resistant cables that meet PV DC requirements in P...

Страница 13: ...on the glass surface of the module reduces its power output and may cause regional hot spots The extent of the effect depends on the transparency of the waste and the small amount of dust on the glass affects absorbing the intensity and uniformity of sunlight but is not dangerous and the power is usually not significantly reduced There must be no environmental impact factors such as the presence o...

Страница 14: ...d or has gaps 8 Others External or otherwise artificially concentrated sunlight shall not be directed onto the front or back face of the PV module Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical applianc...

Отзывы: