OVERVIEW 

 
The  Solexy  RX  series  explosion  proof  and  intrinsically  safe 
antenna  coupler  is  an  integrated  protection  device  that 
facilitates  non-Ex  certified  radio  antenna  installation  in 
hazardous areas. The patented (7.057.577) RX series coupler 
features  a  barrier  circuit  which  blocks  power  voltage  in  the 
event  of  a  radio  transmitter/receiver  fault  and  is 
encapsulated and housed in an explosion proof stainless steel 
body. By limiting transmitted power per local regulations and 
ensuring  the  threshold  power  requirements  for  the  area  of 
installation are met, the RX coupler can easily be used with 
most passive antennas. When a radio must be used in a safe 
area, the RX coupler can still protect the output signal using a 
cable to connect to an antenna that is installed in a hazardous 
area. 
 

Note:  The  information  in  this  manual  is  intended  to  assist 
with equipment design and ensure proper installation. 

 

READ THIS INSTRUCTION FIRST 

 

To  avoid  serious  or  fatal  personal  injury  or  major  property 
damage, read and follow all safety instruction in this manual. 
If you require additional assistance, please contact SOLEXY. 
 

 

SAFETY INSTRUCTION TO HAZARDOUS AREA INSTALLATION 

 

 

The  Solexy  RX  explosion  proof  and  intrinsically  safe 
Antenna  Coupler  must  be  installed  and  maintenance 
according  to  suitable  standards  for  electrical  application 
in  potentially  explosive  atmospheres  (IEC/EN  60079-14, 
IEC/EN60079-17 and/or other national standards). 

 

Suitably  trained  personnel  shall  carry  out  installation 
according with applicable code practice. 

 

Read  this  first  and  keep  this  instruction  manual  always 
available. 

 

For proper installation, see the applicable control drawing 
DDCD-0006 attached. 

 
 

ATEX / IECEx MARKING 

 

I M2 (M1)  Ex db mb [ia Ma] I Mb 
II 2 (1) G  Ex db mb [ia Ga] IIA/IIB/IIC T

6…

T5 Gb 

II 2 (1) D 

Ex mb tb [ia Da] IIIC T80°C

T100°C Db 

 

This  instruction  refers  to  certified  equipment  covered  by 
following certificate: 
 
ATEX: TÜV CY 18 ATEX 0206158 X 
IECEx: IECEx MSC 19.0001X 
 
 
 

 

WARNINGS 

 
1.

 

Solexy RX series antenna coupler must be connected to RF 

source with minimum internal impedance of 50Ω.

 

2.

 

Connected  antennas  must  be  assessed,  installed  and 
maintained according to suitable standards for electrical 
application  in  potentially  explosive  atmospheres  (e.g. 
IEC/EN60079-0,  IEC/EN60079-14,  IEC/EN60079-17  or 
other national standards). 

3.

 

Solexy RX series antenna coupler does not provide any RF 
power limitation. The threshold power must be limited by 
the  user  in  order  to  achieve  the  levels  defined  in 
IEC/EN60079-0 Table 4. 

4.

 

The RX series antenna coupler is designed to be used with 
a  suitable  enclosure  with  mechanical  protection  of  the 
input side that utilizes one of the protection types listed 
in Clause 1 of IEC/EN60079-0 when it is installed in an Ex 
area.  The  protection  type  utilized  shall  be  applicable  to 
the specific area of use (i.e. Gas or Dust). 

5.

 

In  case  of  use  of  a  Ex  tb  enclosure  with  metric  entries 
ensure 5 engaged threads minimum or use an appropriate 
gasket. 

6.

 

In case of use of a Ex tb enclosure with NPT entries ensure 
3,5 engaged threads minimum. 

7.

 

It is responsibility to the installer to ensure an IP6x level at 
the  threaded  joint  between  antenna  coupler  and  Ex  tb 
enclosure. 

8.

 

When  installed  in  a  safe  area  the  input  side  must  be 
protected  from  sun  exposure.  For  example  by  using  a 
housing or by being in an indoor area. 

9.

 

The user should not repair this equipment. 

10.

 

The user should not modify the unit. 

11.

 

The unit should not painted from the user. 

12.

 

If  the  equipment  is  likely  to  come  in  to  contact  with 
aggressive  substances,  it  is  responsibility  of  the  user  to 
take  suitable  precautions  that  prevent  it  from  being 
adversely  affected,  thus  ensuring  that  the  type  of 
protection  is  not  compromised.  Aggressive  substances: 
example Acids, liquids, gases with can affected metals. 

13.

 

Maximum RF power input shall not exceed the value listed 
into control drawing DDCD-0006. 

14.

 

Maximum service temperature (Ts) of RX antenna coupler 
and is 91°C. 

15.

 

Maximum service temperature of equipment it is installed 
in shall not 80°C in case of max RF power input 
(Pi) of 6 W (max T amb a80°C) or +85°C in case of 
max  RF  power  input  (Pi)  of  2  W  (max  T  amb  allowed 
+85°C). 

 
 

INSTALLATION 

 
For  proper  installation,  see  the  applicable 

control  drawing 

DDCD-0006

 

 
 