background image

 

 

 

 

 

Window Preparation 

Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If 
a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit. 

 

Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made 
to fit inside a standard double-hung window. Make sure the window is in good shape and able to firmly hold the needed 
screws. If not, make repairs prior to installing the unit. 

 
 

Model 

WM1-15E-01 

WM1-18E-01 / WM1-24E-01 

Unit Height 

                 17 33/4" 

18 5/8" 

Unit Width 

               23 5/8" 

26 3/8" 

Min.Window Opening(See FIG 
1) 

                   18 4/3" 

19 7/8" 

Min. Window Width 

               28 1/8" 

30" 

Max Window Width 

               41 3/4" 

50 " 

 

 

Storm Window Requirements 

A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To 
adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1 1/2”. 
Make sure the board or piece of wood is 

approximately 1/2” higher than the storm window frame. This will allow the air 

conditioner to tilt enough for proper drainage. (See FIG. 2). 

 

FIG. 1 

FIG. 2 

 
 
 

 

19 7/8"MIN 

 
 
 
 
 
 
 
 
 
 
 

Prior to Installing the Air Conditioner 

1.  Check for anything that could block airflow. Check the area outside of the window for things such as shrubs, trees, or 

awnings. Check the inside area to make sure curtains, drapes, or blinds will not prevent proper airflow. 

2.  Check the available electrical outlet. The power supply must be the same as shown on the unit serial nameplate 

(located on the left side of the unit, near the front faceplate). Be sure the outlet is close enough for the power cord to 
reach. 

3.  Carefully unpack the air conditioner. Remove all packing material and make sure the floor is protected when remov- 

ing. Due to the large size of this air conditioner, two people should move the unit together. 

 

 

When handling the unit, be careful to avoid cuts from 
the sharp metal edges and aluminum fins on the front 
and rear coils. 

18 3/4", / 

18 3/4", / 19 7/8"MIN 

INSTALLATION

ION 

Содержание WM1-15E-01

Страница 1: ...Electronic Window Air Conditioner Operating Instructions V170124 Models WM1 15E 01 15 400 BTU WM1 18E 01 18 300 BTU WM1 24E 01 24 700 BTU...

Страница 2: ...ortant to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the follow...

Страница 3: ...al The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit s...

Страница 4: ...Bottom Rail 1 Owner s Manual 1 Weather Insulation Board 2 CURTAIN CURTAIN LOCK FOAM SEAL FOR BOTTOM RAIL SCREWS AND LOCKNUTS FRAME ASSEMBLY WINDOW SUPPORT BRACKET Weather Insulation Board SILL ANGLE B...

Страница 5: ...ns W x H x D 23 625 x 17 75 x 25 375 Package Dimensions W x H x D 26 125 x 20 x 30 5 Net Gross Weight Lbs 110 121 Refrigerant Type R 410A Plug Type NEMA 5 15P Model WM1 18E 01 WM1 24E 01 Power Supply...

Страница 6: ...NT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN WARNING Avoid fire hazard or electronic shock DO NOT use an extension cord or an adapter plug DO NOT remove any prong from the p...

Страница 7: ...ood to the sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame This will allow the air condi...

Страница 8: ...hese screws will need to be re installed prior to mounting the air con ditioner See Fig 4 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet Remove the ground...

Страница 9: ...side 3 Fasten the curtains to the unit with short screws Fig 10 Window Frame 1 4 Top Rail Bottom Rail Fig 10 Weather Insulation Board Installation NOTE The Weather Insulation Board adds an extra layer...

Страница 10: ...w Insert the sash seal into space between the upper and lower sashes MARK 2 Attach the right angle safety lock as shown below 2 Assemble the sill angle brackets to the support brack ets at the marked...

Страница 11: ...reference Extend the Curtain Panels 1 Carefully raise the window to expose the curtain panel and panel frame Extend the curtain panels to fill the window opening 2 Place the curtain lock between the...

Страница 12: ...an Speed Use the fan speed button to change the fan speed Choose between high medium and low 6 Mode Button Press the MODE button to cycle through the various modes Auto Sleep Energy 7 Auto on Timer Wh...

Страница 13: ...ve Remote colors may differ from image above Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries LCD Display MODE SLEEP FAN HIGH ENERGY SAVER FAN MED TIMER FAN L...

Страница 14: ...ep operating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver li...

Страница 15: ...aver Mode When the Energy Saver mode is ON the fan will cycle on and off with the compressor This re sults more winder variations of room tempera ture and humidity Normally it is used when the room is...

Страница 16: ...nt panel of the air conditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Ne...

Страница 17: ...y engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds...

Страница 18: ...ghtly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with...

Страница 19: ...sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus...