background image

 

 

 
 
 

 

1. 

Freezing Conditions: 

This is a cooling only air 

conditioner. It is not designed for freezing outdoor 
conditions. It must not be used in freezing out- 
door conditions. 

 

2. 

Remote Control: 

To ensure proper operation 

when using the remote control, aim the remote 
directly at the signal receiver on the air condi- 
tioner. 

 

 

The remote control has a signal range up to 20 
feet. 

 

Make sure nothing is blocking the remote control 
signal from being received by the air conditioner. 

 

Make sure the batteries are installed correctly 
and still have power. 

 

3. 

Cooling Mode: 

Use the Cool mode at High, Me- 

dium, Low fan speed when cooling is needed. 
Use the temperature 

or

buttons to set the de- 

sired temperature between 61°F-90°F. 

 

 

Once the temperature is set, the compressor will 
cycle on and off to keep the room temperature 
at the set temperature level. The lower the set 
thermostat temperature, the cooler the room will 
be. The higher the set thermostat temperature, 
the warmer the room will become. 

 

 

For Normal Cooling - set the mode to Cool and 
the Fan to High or Med with the temperature set 
in the Middle. 

 

 

For Maximum Cooling - set the mode to Cool 
and the Fan to High with a lower set tempera- 
ture. 

 

 

For Quieter & Nighttime Cooling - set the mode 
to Cool and the Fan to Low with the temperature 
set in the middle. 

 

4. Energy Saver Mode: 

 

When the Energy Saver mode is 

ON

, the fan will 

cycle on and off with the compressor. This re- 
sults more winder variations of room tempera- 
ture and humidity. Normally, it is used when the 
room is occupied. The fan may continue to run 
for a short time after the compressor cycles off. 

 

 

When the Energy Saver mode is 

OFF

, the fan 

runs all the time in fan or cool mode. 

5. 

Fan Only Mode: 

Use Fan Only mode at High, 

Medium, or Low fan speed to provide air circula- 
tion and filtering without cooling. Since Fan Only 
setting does not provide cool, a set temperature 
cannot be entered. The room temperature will 
appear in the display. 

 

6. 

Loss of Power Protection: 

If power to the air 

conditioner is lost or interrupted, the air condi- 
tioner will automatically restart in the setting last 
used prior to power loss. Timer will be cancelled 
when power is lost or interrupted. You may need 
to set a new timer if desired. 

 

7. 

Air Direction: 

Use the lever on the front air 

vents to adjust the airflow direction. You can di- 
rect the airflow to left, right, up or down. The lever 
is located on the lower left and right side of the 
air vent. 

 

8. 

Auto Mode: 

The air conditioner will automatically 

choose Cool or Fan mode based on current room 
temperature. 

 

9. 

Ventilation: 

In order to maintain the best cooling 

condition, pull the Fresh Air Lever to close the 
vent. When fresh air is necessary, push the 
Fresh Air Lever to open the vent allowing fresh 
air being re-circulated in the room. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fresh Air Lever 

 
 

 

USE THE AIR CONDITIONER 

Содержание WM1-15E-01

Страница 1: ...Electronic Window Air Conditioner Operating Instructions V170124 Models WM1 15E 01 15 400 BTU WM1 18E 01 18 300 BTU WM1 24E 01 24 700 BTU...

Страница 2: ...ortant to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the follow...

Страница 3: ...al The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit s...

Страница 4: ...Bottom Rail 1 Owner s Manual 1 Weather Insulation Board 2 CURTAIN CURTAIN LOCK FOAM SEAL FOR BOTTOM RAIL SCREWS AND LOCKNUTS FRAME ASSEMBLY WINDOW SUPPORT BRACKET Weather Insulation Board SILL ANGLE B...

Страница 5: ...ns W x H x D 23 625 x 17 75 x 25 375 Package Dimensions W x H x D 26 125 x 20 x 30 5 Net Gross Weight Lbs 110 121 Refrigerant Type R 410A Plug Type NEMA 5 15P Model WM1 18E 01 WM1 24E 01 Power Supply...

Страница 6: ...NT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN WARNING Avoid fire hazard or electronic shock DO NOT use an extension cord or an adapter plug DO NOT remove any prong from the p...

Страница 7: ...ood to the sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame This will allow the air condi...

Страница 8: ...hese screws will need to be re installed prior to mounting the air con ditioner See Fig 4 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet Remove the ground...

Страница 9: ...side 3 Fasten the curtains to the unit with short screws Fig 10 Window Frame 1 4 Top Rail Bottom Rail Fig 10 Weather Insulation Board Installation NOTE The Weather Insulation Board adds an extra layer...

Страница 10: ...w Insert the sash seal into space between the upper and lower sashes MARK 2 Attach the right angle safety lock as shown below 2 Assemble the sill angle brackets to the support brack ets at the marked...

Страница 11: ...reference Extend the Curtain Panels 1 Carefully raise the window to expose the curtain panel and panel frame Extend the curtain panels to fill the window opening 2 Place the curtain lock between the...

Страница 12: ...an Speed Use the fan speed button to change the fan speed Choose between high medium and low 6 Mode Button Press the MODE button to cycle through the various modes Auto Sleep Energy 7 Auto on Timer Wh...

Страница 13: ...ve Remote colors may differ from image above Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries LCD Display MODE SLEEP FAN HIGH ENERGY SAVER FAN MED TIMER FAN L...

Страница 14: ...ep operating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver li...

Страница 15: ...aver Mode When the Energy Saver mode is ON the fan will cycle on and off with the compressor This re sults more winder variations of room tempera ture and humidity Normally it is used when the room is...

Страница 16: ...nt panel of the air conditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Ne...

Страница 17: ...y engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds...

Страница 18: ...ghtly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with...

Страница 19: ...sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus...

Отзывы: