background image

 

 

 

INSTALLATION

 

Model

 

WM1

-

05M2

-

02

 

Unit Height

 

11 3/4"

 

Unit Width

 

16 1/8"

 

Min. Window Opening (See FIG 1)

 

12”

 

Min. Window Width

 

20 1/2"

 

Max Window Width

 

34"

 

Window Preparation

 

Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If a new 

electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit.

 

 

Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made to fit 

inside a standard double

-

hung window. Make sure the window is in good shape and able to firmly hold the provided screws. If 

not, make repairs prior to installing the unit.

 

 

Storm Window Requirements

 

A storm window frame will not allow the air conditioner to tilt properly which will keep it from draining properly. To 

adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1 

1/2”. 

Make sure the board or piece of wood is approximately 

1/2” 

higher than the storm window frame. This will allow the air 

conditioner to tilt enough for proper drainage (See FIG. 2).

 

Prior to Installing the Air Conditioner

 

1. Check for anything that could block airflow. Check the area outside of the window for things such as shrubs, trees, 

or awnings. Check the inside area to make sure curtains, drapes, or blinds will not prevent proper airflow.

 

2. Check the available electrical outlet. The power supply must be the same as shown on the unit serial nameplate 

(located on the left side of the unit, near the front faceplate). Be sure the outlet is close enough for the power cord to 

reach.

 

3. Carefully unpack the air conditioner. Remove all packing material and make sure the floor is protected when remov-

ing. Due to the large size of this air conditioner, two people should move the unit together.

 

 

 

When handling the unit, be careful to avoid cuts from the 

sharp metal edges and aluminum fins on the front and rear 

coils.

 

13 1/4" MIN

 

FIG .2

 

 

 

   

FIG .1

 

13 1/4" MIN

 

Содержание WM1-05M2-02

Страница 1: ...er must be upright for 24 hours prior to operating This ensures that the compressor will function as intended Model WM1 05M2 02 5 100 BTU Window Air Conditioner Operating Instructions AIR CONDITIONER...

Страница 2: ...itioner please read this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety...

Страница 3: ...sed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button ci...

Страница 4: ...Rail Foam Seal Insert Strip Short Screw Long Screw Sash Lock Curtain Lock Window Air Conditioner 1 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Long Screw for Locking Bracket Curtains 12 Side Cur...

Страница 5: ...ions W x H x D 16 125 x 11 75 x 15 125 Package Dimensions W x H x D 17 9 x 14 96 x 17 2 Net Gross Weight Lbs 40 7 45 1 Refrigerant Type R 410A Plug Type NEMA 5 15P SPECIFICATIONS Noise level is measur...

Страница 6: ...ENTED IN THIS USER S MANUAL ARE THE PRESENATION OF THE MANUFACTURER SOLEUS N A HAS NOT CONDUCTED AN INDEPENDENT TEST TO VERIFY THE INFORMATION AND SPECIFICATIONS PRESENTED HEREWITHIN WARNING grounding...

Страница 7: ...sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame This will allow the air conditioner to...

Страница 8: ...uter case using four short screws Curtain Installation 1 Insert the side curtains into the upper and lower rails of the air conditioner Fasten the curtains to the unit with short screws as shown below...

Страница 9: ...the air conditioner and window sill This is option al Foam Seal Window Sill Sash Lock Curtain Locks Flange Curtain Remove the Air Conditioner from the Window End of Season 1 Turn the air conditioner o...

Страница 10: ...ettings or turn the selector counter clockwise to select the lower cool settings Turn the MODE selector to OFF to turn off the unit FAN MODE Turn the MODE selector counter clockwise to select HIGH FAN...

Страница 11: ...LOSS OF POWER PROTECTION If power to the air conditioner is lost or interrupted the air conditioner will automatically re start in the setting last used prior to power loss AIR DIRECTION Use the leve...

Страница 12: ...D TEAR To minimize wear and tear on the air conditioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from trippin...

Страница 13: ...not stay engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains...

Страница 14: ...correctly tilted towards the outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture...

Страница 15: ...al handling provisions in the in structions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those aut...

Отзывы: