ASSEMBLY & INSTALLATION (CONT.) 

Curtain & Weather Insulation Board Installa-
tion 

NOTE: 

The Weather Installation Board adds an extra layer of 

insulation to keep air from passing through the sides of the win-
dow air conditioner. 

1.  Using a sharp blade or scissors, slowly cut the           

Weather Insulation Board to a size that will fit inside of 
the side curtain rails and completely cover the curtain. 

 

2. Once properly sized, remove the backing to expose       

the adhesive tape.  

 
3. Place the Weather Insulation Board over the left curta-    

in and firmly press and hold for 5 seconds.  

 
4. Place the Weather Insulation Board over the right curt- 

ain and firmly press and hold for 5 seconds.(FIG. 1) 

 
 

 
 
 
 

 
 
 
 
5. Insert the side curtains into the upper and lower rails of 

the air conditioner. Fasten the curtains to the unit with-
short screws as shown below: 

6. Slide the free end of the curtain into the side panel of 

the air conditioner. Do this for each side. The flange 
for securing the curtain into the window sill will be fac-
ing the room side when installed. 

Placing the Unit Inside a Normal Window 

  

2. Once the air conditioner is placed, extend the left and 

right curtains to the width of the window. 

 
3. Place the curtain lock between the curtain extensions 

and the window sill, drive long screws through the lock 
and into the sill as shown below: 

4. Secure the left and right flanges on end bottom side of 

the curtain with long screws. 

 

5. Drive long screws through upper frame holes into win-

dow sash. 

 
6. Attach the sash lock to the place between the upper  

and lower sashes and secure it with long screws. Each 
side uses 2 long screws. 

 

7. Cut the foam seal to the window width and insert the 

sash seal between the glass and the window to pre-
vent air and insect from getting into the room. 

 
8. For added insulation, the insert strip can be inserted  

between the air conditioner and window sill. This is 
optional. 

FIG.1 

Weather Insulation 
Board 

1.  Set the unit  in the window so that is centered. Place 

the unit so that from edge of the bottom rail is against 
the back edge of the sill. 

 
2.   Bring the window down so that the front edge of the 

top rail is in front of the window. Be sure the unit is 
tilting slightly to the outside. 

1/4” 

Bottom Rail 

Top Rail 

Window 
Frame 

Содержание WM1-05M-01

Страница 1: ...Model WM1 05M 01 Window Air Conditioner Operating Instructions 54 000 BTU...

Страница 2: ...owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in thi...

Страница 3: ...nd or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Pre...

Страница 4: ...st Window Air Conditioner 1 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Curtain 2 Sash Lock 2 Foam Seal 1 Long Screw for Window Locking Bracket Curtains 12 Curtain Lock 2 Owner s Manual 1 Weather...

Страница 5: ...ay Product Dimensions W x H x D 18 625 x 12 625 x 15 5 Package Dimensions W x H x D 23 x 15 x 18 625 23 x 18 625 x 15 Net Gross Weight Lbs 46 55 46 55 Refrigerant Type R 410A R 410A Plug Type NEMA 5 1...

Страница 6: ...ED INDEPENDENT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 5 Power supply cord with 3 prong grounding plug and current detection device WARNING Avoid fire hazard or electronic...

Страница 7: ...imately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could...

Страница 8: ...utilization and drainage If you are not using the side panels the rear pitch must still be maintained 1 Attach the top rail onto the top of the outer case using four Short Screws 7 m o u n t i n g r...

Страница 9: ...en installed Placing the Unit Inside a Normal Window 2 Once the air conditioner is placed extend the left and right curtains to the width of the window 3 Place the curtain lock between the curtain ext...

Страница 10: ...sash seal from between windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels into frame 5 Keeping a firm grip on air conditioner r...

Страница 11: ...ter clockwise to select the lower cool settings Turn the MODE selector to OFF to turn off the unit Fan Mode Turn the MODE selector counter clockwise to select HIGH FAN MED FAN or LOW FAN Turn the MODE...

Страница 12: ...ior to power loss Timer will be cancelled when power is lost or interrupted You may need to set a new time if desired Air Direction Use the lever on the front air vents to adjust the airflow direction...

Страница 13: ...o minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabin...

Страница 14: ...ngaged discontinue use of the air conditioner and contact a qualified service technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control ma...

Страница 15: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 16: ...rmal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus Home Comfort maintains a centralized service network to provide parts and assist in resolving service proble...

Отзывы: