background image

WARRANTY 

 

One Year Limited Warranty 
 

Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects 
in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year 
from the date of original retail purchase in the United States. 
 
If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of 
charge within a reasonable time after the unit is returned during the warranty period. 
 
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a 
copy of the original purchase invoice. 
 

THIS WARRANTY DOES NOT COVER:

 

• 

Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in 
material or workmanship.  

• 

Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions 
in the instructions. 

• 

Damage to the finish of the case, or other appearance parts caused by wear. 

• 

Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-
tional Inc. 

• 

Freight and Insurance cost for the warranty service. 

• 

Filter and Accessories 

 
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO 
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY

. SOLEUS INTERNATIONAL INC.

  

DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT 
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR 
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT. 
 

This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-
vaged, or refurbished products. 

 
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow  
limitation on implied warranties, the above limitations and exclusions may not apply to you.  This warranty gives you 
specific legal rights, and you may also have other rights that vary from state to state. 
 

For Technical Support and Warranty Service 

Please Call (888) 876-5387  
 
Or Write To: 
Soleus International, Inc. 
20035 E. Walnut Dr. N. 
City of Industry, CA 91789 
www.soleusair.com 
www.soleusgreen.com 
 

 21 

www.sylvane.com  1-800-934-9194

Содержание SG-WAC-15ESE-C

Страница 1: ...Models SG WAC 15ESE C SG WAC 18ESE C Electronic Window A C Operating Instructions www sylvane com 1 800 934 9194...

Страница 2: ...manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner...

Страница 3: ...aced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A dam...

Страница 4: ...ncil Level Socket Wrenches Phillips Head Screwdriver Non Hardware Packing List Window Air Conditioner AAA Batteries 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retain...

Страница 5: ...erage 12 8 1 8 8 EER C O P 10 7 10 7 10 7 Noise Level dB A H M L 61 59 51 61 59 51 CFM H M L 470 430 390 470 430 390 Dehumidifying Capacity 100 8 Pints per day 132 Pints per day Product Dimensions W x...

Страница 6: ...Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees or awnings Check the inside area to make sure...

Страница 7: ...the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the fac...

Страница 8: ...to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the...

Страница 9: ...shipping screws from the top of the unit and the right side of the cabinet if installed FIG 6 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift nea...

Страница 10: ...Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle rail 4 Install top angle sid...

Страница 11: ...shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accordion panels slid...

Страница 12: ...below MAX WALL THICKNESS 10 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long mi...

Страница 13: ...he dry wall NOTE If wall thickness is 8 1 2 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall Prepare and...

Страница 14: ...or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in place using mason...

Страница 15: ...t the Auto on Timer press the DELAY button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET light will...

Страница 16: ...cooling to begin Heat Mode Use the Heat mode at Low Med High or Auto Fan Speed for heating Use the temperature buttons to set the desired temperature between 64 F and 86 F in 1 F increments For Normal...

Страница 17: ...ith the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3...

Страница 18: ...e wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabinet Cleani...

Страница 19: ...OUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escapin...

Страница 20: ...age make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is...

Страница 21: ...used by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES...

Отзывы: