background image

 
 
 

 

 

 
 
 
 
 
 
 

 

 

 17 

USING YOUR AIR CONDITIONER 

(Cont.) 

• 

Freezing Conditions: 

This is a cooling only air 

conditioner. It is not designed for freezing outdoor 
conditions. It must not be used in freezing outdoor 
conditions. 

• 

Remote Control: 

To ensure proper operation 

when using the remote control, aim the remote 
directly at the signal receiver on the air condi-
tioner. 

• 

The remote control has a signal range up to 
20 feet.   

• 

Make sure nothing is blocking the remote con-
trol signal from being received by the air con-
ditioner. 

• 

Make sure the batteries are installed correctly 
and still have power. 

• 

Cooling Mode: 

Use the COOL mode at Low, Me-

dium, High, or Auto Fan speed when cooling is 
needed. Use the temperature 

/

 buttons to set 

the desired temperature between 64°F and 86°F.  

• 

Once the temperature is set, the compressor 
will cycle on and off to keep the room 
temperature at the set temperature level. The 
lower the set thermostat temperature, the 
cooler the room will become. The higher the 
set thermostat temperature, the warmer the 
room will become. 

• 

For Normal Cooling - Set the Mode to 

Cool 

and the Fan to 

High 

or 

Med 

with the 

termperature set in the middle. 

• 

For Maximum Cooling - Set the Mode to 

Cool 

and the Fan to 

High 

with a lower set 

temperature. 

• 

For Quieter & Nighttime Cooling - Set the 
Mode to 

Cool 

and the Fan to 

Low 

with the 

temperature set in the middle. 

NOTE: 

If the air conditioner is off and is then 

turned on while set to a Cool setting or if 
turned from a fan setting to a Cool setting, it 
may take approximately 3 minutes for the 
compressor to start and cooling to begin. 

• 

Energy Saver Mode 

- Controls the Fan 

On 

- The fan will cycle on and off with the            

compressor. This results in winder variations of room 
temperature and humidity. Normally used with the 
room is unoccupied. NOTE: The fan my continue to 
run for a short time after the compressor cycles off. 

Off 

- The fan runs all the time in fan or cooling mode. 

 

• 

Fan Only Mode: 

Use 

Fan Only 

mode at 

Low

Med

, or 

High 

fan speed to provide air circulation 

and filtering without cooling. Since fan only setting 
do not provide cooling, a 

Set 

temperature cannot 

be entered. The room temperature will appear in 
the display.  

      NOTE: 

Auto Fan 

Speed cannot be used in 

Fan    

Only 

mode. 

• 

Loss of Power Protection: 

If power to the air 

conditioner is lost or interrupted, the air condi-
tioner will automatically re-start in the setting last 
used prior to power loss. If the Timer was set to 
automatically turn the air conditioner off or on, it 
will resume countdown at the amount time left 
prior to power loss. You may need to set a new 
time if desired. 

• 

Air Direction: 

Use the lever on the front air vents 

to adjust the direction of the airflow. You can di-
rect the airflow left, right, up or down. The lever is 
located on the right side of the air vent. 

 

www.sylvane.com  1-800-934-9194

Содержание SG-WAC-15ESE-C

Страница 1: ...Models SG WAC 15ESE C SG WAC 18ESE C Electronic Window A C Operating Instructions www sylvane com 1 800 934 9194...

Страница 2: ...manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner...

Страница 3: ...aced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A dam...

Страница 4: ...ncil Level Socket Wrenches Phillips Head Screwdriver Non Hardware Packing List Window Air Conditioner AAA Batteries 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retain...

Страница 5: ...erage 12 8 1 8 8 EER C O P 10 7 10 7 10 7 Noise Level dB A H M L 61 59 51 61 59 51 CFM H M L 470 430 390 470 430 390 Dehumidifying Capacity 100 8 Pints per day 132 Pints per day Product Dimensions W x...

Страница 6: ...Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees or awnings Check the inside area to make sure...

Страница 7: ...the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the fac...

Страница 8: ...to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the...

Страница 9: ...shipping screws from the top of the unit and the right side of the cabinet if installed FIG 6 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift nea...

Страница 10: ...Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle rail 4 Install top angle sid...

Страница 11: ...shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accordion panels slid...

Страница 12: ...below MAX WALL THICKNESS 10 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long mi...

Страница 13: ...he dry wall NOTE If wall thickness is 8 1 2 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall Prepare and...

Страница 14: ...or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in place using mason...

Страница 15: ...t the Auto on Timer press the DELAY button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET light will...

Страница 16: ...cooling to begin Heat Mode Use the Heat mode at Low Med High or Auto Fan Speed for heating Use the temperature buttons to set the desired temperature between 64 F and 86 F in 1 F increments For Normal...

Страница 17: ...ith the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3...

Страница 18: ...e wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabinet Cleani...

Страница 19: ...OUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escapin...

Страница 20: ...age make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is...

Страница 21: ...used by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES...

Отзывы: