USING YOUR AIR CONDITIONER 

Electronic Control Panel & Remote Control 
 
 
 

 

1. 

Power Button: 

Turns the air conditioner on and 

off 

2. 

Digital Display: 

Displays the current room tem-

perature or the amount of time left on the timer. 
Shows the Set Temp when setting the tempera-
ture. Shows the Timer Set when setting the timer. 
The once the timer and/or temperature are set, 
the display will change to show the current room 
temperature. To see the set temperature again, 
simply press either of the Temp/Delay 

/

 

buttons. 

 

 

3. 

Temperature Set: 

Use these buttons on the con-

trol panel and remote to increase or decrease the 
Set Temperature (the desired room temperature) 
in cooling or energy saver mode. The 

SET 

light 

will light up when setting the temperature 

4. 

Timer Set: 

Use these buttons on the control 

panel and remote to set the Timer. Each press of 
the Timer (

DELAY

) buttons will increase or de-

crease the timer. For timer instructions see #7. 

5. 

Fan Speed & Auto Fan

: Use the fan speed but-

tons to change the fan speed. Choose between 
low, medium, high, and Auto. When using the re-
mote control, press the 

AUTO 

button to turn auto 

mode on and off and the 

FAN+ 

and 

FAN– 

buttons 

to select low, medium, or high fan speed. 

6. 

Mode Button: 

Press the mode button to cycle 

through the various modes: Cooling, Energy 
Saver, Fan only, and Dry (Dehumidifier). 

7. Auto-on 

Timer: 

When the air conditioner is off, it 

can be set to automatically turn on in 1-24 hours 
at the previous set mode and fan setting. To set 
the Auto-on Timer, press the 

TIMER 

button on the 

unit or remote control. Each touch of the 

/

 on 

the unit or the +/- buttons on the remote will 
change the timer setting in 1 hour intervals. The 

SET 

light will turn on while setting.

 

Auto-off Timer: 

When the air conditioner is on, it 

can be set to automatically turn off in 1-24 hours. 
To se the Auto-off Timer, press the 

TIMER 

button 

on the unit or remote control. Each ouch of the 

/

 on the unit or the +/- buttons on the remote will 

change the timer setting in 1 hour intervals. The 

SET 

light will turn on while setting. 

• 

To see the remaining time, press the 

TIMER 

Button. To change the timer setting use the 

/

 on the unit or the +/- buttons on the 

remote. 

• 

To cancel the timer, press the 

TIMER 

button 

until the 

SET 

light turns off.

 

8. 

Filter Check: 

After the fan rotates for 250 total 

hours, the filter check light will turn on to remind 
the user to clean the filter. Press the Filter check 
button once the filter is cleaned to reset the re-
minder.

 

Air Conditioner Controls 

NOTE: This display always shows the room temperature 

except when setting the Set temperature or the Timer. 

When the light is on the unit is in 

temperature or timer set mode. 

Normal Operating Sounds 

• 

You may hear a pinging noise caused by water 
hitting the condenser, on rainy days, or when the 
humidity is high. This design feature helps re-
move moisture and improve efficiency.  

• 

You may hear the thermostat click when the com-
pressor cycles on and off. 

• 

Water will collect in the base pan during rain or 
days of high humidity. The water may overflow 
and drip from the outside part of the unit. 

• 

The fan may run even when the compressor is 
not on. 

Содержание SG-WAC-06ESE-F

Страница 1: ...Models SG WAC 06ESE F SG WAC 08ESE F Electronic Window Air Conditioner Operating Instructions...

Страница 2: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 3: ...hen the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A damaged power supply cord mus...

Страница 4: ...nditioner Remote Control AAA Batteries 2 Top Mounting Rail Top Mounting Rail Seal Strip 2 5 Screw for Top Mounting Rail 4 Accordion Panels Left Right Sash Lock 1 Window Sash Seal 4 5 Screw for Window...

Страница 5: ...NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 5 Model SG WAC 06ESE F Power Supply Ph V Hz 1 115 60Hz Rated Cooling Capacity BTU h 6 300 Cooling Power I...

Страница 6: ...ensions 3 The Lower Sash the lower part of the window that moves up and down must allow for 14 5 of vertical clearance when open See FIG 1 4 All supporting parts must be secured to firm wood masonry o...

Страница 7: ...roper condensation utilization and drainage If you are not using the side panels the rear pitch must still be main tained 1 Remove the backing from the top mounting rail seal strip and attach the seal...

Страница 8: ...attach the window air conditioner to the lower sash See FIG 8 9 Accordion Panel Installation Now that you have installed the top rail you can now install the accordion panels on each side 1 Place the...

Страница 9: ...oximately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drain age See FIG 12 Removing the Air Conditioner from the Window 1 Turn the air conditio...

Страница 10: ...tting To set the Auto on Timer press the TIMER button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET...

Страница 11: ...ioner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be...

Страница 12: ...nd buttons a the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit is in...

Страница 13: ...he Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take...

Страница 14: ...Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from trippin...

Страница 15: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 16: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 17: ...y wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories...

Отзывы: