V180131

 

3058080

 

Air conditioner must be upright for 24 hours prior to operating. 

This ensures that the compressor will function as intended.

 

Содержание PSR-06-01

Страница 1: ...V180131 3058080 Air conditioner must be upright for 24 hours prior to operating This ensures that the compressor will function as intended ...

Страница 2: ...in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop...

Страница 3: ... 1 Exhaust Hose 1 Exhaust Hose Connector 1 Window Kit Panel 3 Window Kit Adapter 1 Wing Nut 2 Optional Drain Tube 1 Drain Tube Stopper 1 Remote Control 1 AAA Battery 2 Owner s Manual 1 Optional Window Security Pack 1 PACKAGE CONTENTS SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 95 F WB 83 F Noise level is measured at a distance of 3 28 ft away from the front of t...

Страница 4: ...ed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button circuit should trip cutting power to the air conditioner When this occurs the LED light will turn off 3 Press RESET button to restore power to the unit Once power is restored the LED light will turn on a...

Страница 5: ... 7 Hot Air Discharge Opening 8 Air Intake Grille 9 Condensation Drain Hole 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter 13 Window Kit Panels 14 Wing Nuts 15 Optional Drain Tube 16 Drain Tube Stopper 17 Remote Control 18 Batteries 19 Optional Window Security Pack MODEL PSR 06 01 PSR 08 01 PSR 10 01 ...

Страница 6: ...he unit in air conditioning dehu midification When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and ex haust hose do not need to be installed when the unit is used as a fan The supplied window kit can be installed in sliding windows and sliding glass doors up to 7 ft long approximate length When installed be sure to keep the exhaust hose and short and straig...

Страница 7: ... WINDOW KIT ASSEMBLY ...

Страница 8: ... the opening If necessary mark the kit and cut one end down to properly fit the opening 2 Twist the Exhaust Hose Connector over the discharge opening on the back of the unit and extend the Exhaust Hose Keep the exhaust hose as short and straight as possible 3 Attach the Window Kit Adapter to the Exhaust Hose Then attach the Window Kit Adapter to the Window Kit panel Close the window or door tightl...

Страница 9: ...ion Your Window Kit also includes an optional security bracket that can be installed to prevent the window from being opened from the outside while a Window Kit is installed SECURITY BRACKET Single and Double Hung Windows Sliding Windows ...

Страница 10: ...ntil it is changed by the user The temperature indicator display shows temperature in Fahrenheit While the unit is plugged in but not powered on press and hold the and buttons for 3 seconds to switch between Celsius and Fahrenheit 4 Fan Speed Press FAN SPEED button to choose fan speed in High Medium or low 5 Timer Press TIMER button to set the unit automatically turn ON or OFF Use the and buttons ...

Страница 11: ...REMOTE CONTROL LCD DISPLAY POWER BUTTON REMOTE LOCK BUTTON SLEEP BUTTON TIMER BUTTON TURBO COOL BUTTON C F SWITCH BUTTON MODE BUTTON FAN SPEED MY TEMP BUTTON TIMER TEMP INCREASE TIMER TEMP DECREASE ...

Страница 12: ...he SLEEP Button on the remote control Sleep mode icon will show on the remote control LCD display When in SLEEP mode the fan will run on low to keep fan noise at a minimum The temperature setting will gradually increase to 2 F above the origi nal set temperature each of first 2 hours The unit will keep operating the same temperature until the sleep mode is turned off 6 TIMER Auto On Press the TIME...

Страница 13: ... also improve the cool ing efficiency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the dehumidi...

Страница 14: ...ank holds approximately 1 5 liters of water When this tanks becomes full the unit will automatically shutdown and illuminate the Bucket Full indicator Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Press the MODE button until the fan mode indicator lights up on the control panel display 4 Select the fan speed by press...

Страница 15: ...te water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain hole to stop the water flow 5 Empty the drain pan 6 Repeat steps 2 5 until all the water is emptied NOTE Once the condensate tank has been emptied firmly press the drain plug back onto the condensa tion drain hole Fig 15 1 It is not advised to use continuous drainage when the...

Страница 16: ...an the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the drain plug in the back of the unit located at the bot tom 2 Unplug the unit 3 The unit should be stored in a cool dry ...

Страница 17: ...tly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes have elapsed sinc...

Страница 18: ... Error Code Possible Causes Solution E2 Indoor Temperature Sensor Failure Turn the unit on and off to remove error code If this code appears again please call customer service at 877 665 9765 E3 Coil Pipe Sensor Failure Please call customer service at 877 665 9765 E4 Fan motor Failure Refrigerant low Unit shuts off please call customer service at 877 665 9765 ...

Страница 19: ...provi sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus N A Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS ...