background image

 

 

 

.

 

 

 

WINDOW KIT ASSEMBLY

 

Содержание PMC-12HP-201

Страница 1: ...Portable Air Conditioner with Heat Pump 12 000 BTU 14 000 BTU OPERATING INSTRUCTIONS V170123 PMC 12HP 201 PMC 14HP 201 3058080 ...

Страница 2: ...in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop...

Страница 3: ...t speed setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the environment temperature is higher than the max operating temperature or lower than the mini mum operating temperature the air conditioner may not work properly Model Number PMC 12HP 201 PMC 14HP 201 Capacity Cool Heat 12 000 10 000 14 000 11 000 Dehumidificati...

Страница 4: ...exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button circuit should trip cutting power to the air conditioner When this occurs the LED light will turn off 3 Press RESET button to restore power to the unit Once power is restored the LED light will turn...

Страница 5: ...Grille 9 Condensation Drain Hole 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter Grille 13 Window Kit Adapter 14 Optional Window Kit Adapter Extension 15 Window Kit Panel 16 Wing Nuts 17 Optional Drain Tube 18 Drain Tube Stopper 19 Remote Control 20 Battery 21 Optional Window Security Pack PRODUCT DIAGRAM MODEL PMC 12HP 201 PMC 14HP 201 ...

Страница 6: ...the unit in air conditioning dehu midification and heating modes When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit is used as a fan The supplied window kit can be installed in sliding windows and sliding glass doors up to 7 ft long approximate length When installed be sure to keep the exhaust hose an...

Страница 7: ... WINDOW KIT ASSEMBLY ...

Страница 8: ...Panels to fit the opening If necessary mark the kit and cut one end down to properly fit the opening 3 Twist the Exhaust Hose Connector over the discharge opening on the back of the unit and extend the Exhaust Hose Keep the exhaust hose as short and straight as possible 4 Attach the Exhaust Hose to the Window Kit Adapter Now connect the Optional Window Kit Adapter Extension to the Window Kit Adapt...

Страница 9: ...ion Your Window Kit also includes an optional security bracket that can be installed to prevent the window from being opened from the outside while a Window Kit is installed SECURITY BRACKET Single and Double Hung Windows Sliding Windows ...

Страница 10: ...g until it is changed by the user The temperature indicator display shows temperature in Fahrenheit While the unit is plugged in but not powered on press and hold the and buttons for 3 seconds to switch between Celsius and Fahrenheit 4 Fan Speed Press FAN SPEED button to choose fan speed in High Medium or low 5 Timer Press TIMER button to set the unit automatically turn ON or OFF Use the and butto...

Страница 11: ...LCD DISPLAY POWER BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE REMOTE LOCK BUTTON SLEEP BUTTON TIMER BUTTON TURBO COOL BUTTON C F SWITCH BUTTON MODE BUTTON FAN SPEED MY TEMP BUTTON REMOTE CONTROL ...

Страница 12: ... mode icon will show on the remote control LCD display When in SLEEP mode the fan will run on low to keep fan noise at a minimum The temperature setting will gradually increase to 2 F above the origi nal set temperature each of first 2 hours The unit will keep operating the same temperature until the sleep mode is turned off 6 TIMER Auto On Press the TIMER button when the unit is off to set up the...

Страница 13: ...the MODE button until the dehumidifier mode indicator lights up on the control panel display 5 Temperature indicator displays room temperature NOTE The unit operates at low fan speed during dehumidifier mode The unit cools room slightly dur ing the dehumidification process Keep the windows and doors closed to aid the effective ness of the unit in removing the moisture from the room NOTE When the u...

Страница 14: ...the control panel display 4 Select the fan speed by pressing the FAN SPEED button NOTE It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode Sleep Mode 1 Install the exhaust hose and window kit properly see pages 8 9 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 4 Press the MODE...

Страница 15: ... inside the unit The internal water tank holds approximately 1 5 liters of water When this tanks becomes full the unit will automatically shutdown and illuminate the Bucket Full indicator HOW TO INSTALL CONTINUOUS DRAIN OPTION 1 Place the Portable AC on a level surface 2 Remove the cap on continuous drain port on the back of the unit to access the Continuous Drain Port 3 Thread a garden hose not s...

Страница 16: ...te water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain hole to stop the water flow 5 Empty the drain pan 6 Repeat steps 2 5 until all the water is emptied NOTE Once the condensate tank has been emptied firmly press the drain plug back onto the con densation drain hole Fig 16 1 It is not advised to use continuous drainage when the...

Страница 17: ...an the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the drain plug in the back of the unit located at the bot tom 2 Unplug the unit 3 The unit should be stored in a cool dry ...

Страница 18: ...tly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes have elapsed sinc...

Страница 19: ...SELF DIAGNOSIS The unit has a self diagnosis system to identify a number of malfunctions Error codes are displayed on the appliance display SELF DIAGNOSIS CODES ...

Страница 20: ...provi sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus N A Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS ...

Отзывы: