SPECIFICATIONS 

• 

The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. 

• 

Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode. 

• 

Power consumption is measured when the fan runs at the highest speed setting. 

• 

These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. 

• 

If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, 
the air conditioner may not work properly. 

 

DISCLAIMER 

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE 
PRESENTATION OF THE MANUFACTURER.  SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT 
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.

 

 

 
 
 

PACKAGE CONTENTS 

Portable Air Conditioner 
Exhaust Hoses (1) 
Hose Adapters (1) 
Window Kit Adapter (1) 
HEPA Filter (1) 
Remote Control 
AAA Batteries (2) 
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels) 
Owner’s Manual 

MODEL

 

PA1-12R-32

 

Cooling Capacity 

12,000 BTU/Hr 

Heating Capacity 

12,500 BTU/Hr 

Dehumidifying Capacity 

63 pts/day 

Air Purifier Capacity 

Removes 99.97% Microns 

Power Consumption 

Cooling 1387 

Watts 

Heating 1180 

Watts 

Air Flow Volume 

265 CFM 

Power Source 

115 V / 60 HZ 

Rated Current 

Cooling 12.7 

Heating 10.8 

Sound Pressure Level 

<50db(A) 

Weight 86.9 

lbs 

Dimensions (WxDxH) 

17.87”x14.3”x32.1” 

Refrigerant R22 

PA1-14R-32 

14,000 BTU/Hr 
14,500 BTU/Hr 
63 pts/day 

Removes 99.97% Microns 
1485 watts 

1200 Watts 

265 CFM 
115 V / 60 HZ 
13.6 A 
11 A 
<50db(A) 
86.9 lbs 

17.87”x14.3”x32.1” 

R22 

Содержание PA1-12R-32

Страница 1: ...2008 Soleus Air International Portable Air Conditioner Heat Pump Heater Dehumidifier Fan HEPA Air Purifier PA1 12R 32 PA1 14R 32 Operating Instructions Model No PA1 12R 32 PA1 14R 32 3046364...

Страница 2: ...er please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or...

Страница 3: ...LEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN PACKAGE CONTENTS Portable Air Conditioner Exhaust Hoses 1 Hose Adapters 1 Window Ki...

Страница 4: ...in Plug F HEPA Air Purifier Storage BACK A Hot air outlet grill B Lower air inlet grill C HEPA Air Purifier Holder D HEPA Air Purifier ACCESSORIES Flexible exhaust hose with 2 adapters 3 piece set str...

Страница 5: ...event any sharp bends in the exhaust hose as this will trap hot exhaust air The hot exhaust air can be vented through the wall or out a window If mounting in the wall the height of the hole should be...

Страница 6: ...ounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if t...

Страница 7: ...ndow kit is not long enough connect the extra window kit panel to fit the opening Mark and cut down a single panel of the window kit if necessary Place the window kit between the window and the window...

Страница 8: ...LLATION cont d NOTE The Portable Air Conditioner above may differ from the unit described in this manual The above directions and images show general directions for all Soleus Air single hose portable...

Страница 9: ...OPERATING INSTRUCTIONS CONTROL PANEL MULTI COLOR DISPLAY TEMP AND TIMER INDICATOR OSCILLATION ON BUCKET FULL SLEEP MODE ON COMPRESSOR ON TIMER OFF MULTI COLOR DISPLAY AUTO A C DEHUM TIMER ON HEATER FA...

Страница 10: ...auto off timer press the TIMER button until the display shows a flash ing when the unit is on Press the or buttons to change the clock to the desired time for the unit to automatically turn off To pr...

Страница 11: ...orm in dehumidifier mode when the room temperature is lower than 61 F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Pr...

Страница 12: ...n Air Conditioner mode 2 Press the SLEEP Button on the remote control The icon appears on the control panel display 3 When in SLEEP mode the fan will run on low to keep fan noise at a minimum 4 When i...

Страница 13: ...ir filter is installed replace the Air Filter Holder on the back of the unit 6 Turn the unit on by pressing either the POWER button on the remote or control panel or the PURIFY button on the control p...

Страница 14: ...PERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED SWING LOUVER OSCILLA...

Страница 15: ...he speed label Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control 4 Temperature Setting When the unit is in Air Conditioner or Heating...

Страница 16: ...sate tank holds approximately 1 5 Liters of water Another option is to purchase a small hose from a hardware store that can fit around the 5 8 drain plug on the back of the unit and drain the unit int...

Страница 17: ...ral detergent Rinse the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new fi...

Страница 18: ...pearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service...

Отзывы: