PROBLEM

 

 

CAUSE

 

 

SOLUTION

 

 

 Air conditioner does not 

 

 power on

 

• 

Unit is not plugged in

 

• 

No electric current to outlet

 

• 

Internal safety device has tripped

 

• 

Plug unit in.

 

• 

Check electric breaker box for a 

trip

 

• 

Wait 30 minutes for safety de-

vice to reset

 

Air conditioner works for a   

limited amount of time

 

• 

There are bends in the exhaust 

hose

 

• 

Something is blocking the air 

 

 from being discharged

 

• 

Position the air exhaust hose 

correctly, keeping it as short and 

free of curves as possible

 

• 

Check and remove anything 

obstructing air discharge

 

 During operation, there is an  

unpleasant smell in the room

 

• 

Air filter is dirty

 

• 

Remove air filters, clean and 

 

 re

-

install

 

 Air conditioner does not oper-

ate after restarting the unit

 

• 

The internal compressor safety de

-

vice prevents the unit from being 

restarted until three minutes have 

elapsed since it was last turned off

 

• 

Wait for compressor to turn on

 

 The control panel display 

 

shows Error codes

 

• 

The unit has a self diagnosis

 

system to identify a number of

 

malfunctions

 

• 

See page 18 Self

-

Diagnosis 

 

TROUBLESHOOTING

 

Содержание LX-140 NT

Страница 1: ...V180320 4010450 Air conditioner must be upright for 24 hours prior to operating This ensures that the compressor will function as intended...

Страница 2: ...ays place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 20 inches 50 cm clearance spa...

Страница 3: ...d setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the environment temperature is higher than the max operating temperatu...

Страница 4: ...xposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button...

Страница 5: ...PRODUCT DIAGRAM 16 Remote Control Battery Intake hose connector...

Страница 6: ...idification and heating modes When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and exhaust hoses do not need to be installed when the unit is used as a fan The...

Страница 7: ...Nuts after adjusting the length of the panel according to the height of the window 1 Using Panel B to connect Panel A C by placing the Wing Nut Base on Panel A C 3 Connect the exhaust hoses to the win...

Страница 8: ...the window or door to adjust the length of the Window Kit Panels to fit the opening If necessary mark the kit and cut one end down to properly fit the opening 3 Twist the Exhaust Hose Connector over...

Страница 9: ...After the temperature is set the unit will display this temperature setting until it is changed by the user The temperature indicator display shows temperature in Fahrenheit While the unit is plugged...

Страница 10: ...LCD DISPLAY POWER BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE SLEEP MODE BUTTON TIMER BUTTON SWING BUTTON MODE BUTTON FAN SPEED REMOTE CONTROL...

Страница 11: ...s the or to select your desired temperature setting The temperature on the LCD display on the remote control will increase or decrease accordingly 5 SLEEP MODE When in air conditioning mode press the...

Страница 12: ...d window kit and keeping direct sunlight to a minimum will also improve the cool ing efficiency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented o...

Страница 13: ...aid the effectiveness of the unit in removing the moisture from the room NOTE When the unit is running on dehumidifier mode the exhaust hose is required and must be vented outside using the supplied w...

Страница 14: ...ll accumulate in an internal water tank inside the unit When this tanks becomes full the unit will automatically shutdown and illumi nate the Bucket Full indicator HOW TO INSTALL CONTINUOUS DRAIN OPTI...

Страница 15: ...he unit 3 Remove the drain plug from the condensation drain hole The condensate water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain...

Страница 16: ...ng 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or...

Страница 17: ...ly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filte...

Страница 18: ...it on and off to remove error code If this code appears again please call customer service at 877 976 5387 E2 Indoor Temperature Sensor Failure Turn the unit on and off to remove error code If this co...

Страница 19: ...sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by SoleusA...

Отзывы: