background image

4

water tank float lid should be able to
move up and down freely after correct
installment.

d)

Insert the complete water tank back to
the air conditioner unit.

2)

Exhaust Duct

When you use the unit as an air conditioner, the hot exhaust air must be directed out of the room.
The exhaust duct is used to allow the hot air out.  DO NOT INSTALL OR USE THE EXHAUST
DUCT WHEN THE UNIT IS OPERATED AS A DEHUMIDIFIER OR FAN.

a)

Slid exhaust connector all the way down over
the discharge opening of the unit.

b)

Mount the external end of the exhaust duct
onto a hole of 5 ¼” (132 mm) on the wall for
optional wall hot air outlet installation, or

c.) Connect the window kit adaptor to the external end of the

exhaust duct for a window or sliding door hot air outlet
installation.

NOTE: In order to increase the efficiency, the exhaust duct should
be keep as short and straight as possible.  The exhaust hose can be
cut shorter by unthreading either end of the exhaust duct counter
clockwise. It is not recommended to increase the manufacturer’s
length of the exhaust hose. This may impede or damage the unit.

3)

Window Kit Installation

a)

Open window or sliding door for approximately 5 inches (130 mm)

b)

Adjust the length of the window kit to the same length of the window or the sliding door.
Use all three panels if necessary.

c)

Use screws to affix the window kit length.

d)

Place the window kit to the window or sliding door. Close the window or door as far as
 it goes.

e)

Mount the window kit extension of the exhaust host onto the window kit.

Fig.1 c)

Fig.2 a)

Window,

slidingdoor or

Wall

Fig.2 b)-c)

Содержание KY-320

Страница 1: ......

Страница 2: ...BEFORE USE 3 CONTROL PANEL AND LCD DISPLAY 5 CONTROL PANEL FUNCTIONS 6 OPERATION USING CONTROL PANEL 7 OPERATION USING REMOTE CONTROLLER 8 CONDENSATEWATERDRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 14...

Страница 3: ...use your portable air conditioner please read this operation manual carefully 1 Never use or store gasoline or other flammable vapor or liquid near this unit 2 Maintain at least 10 25 CM clearance sp...

Страница 4: ...ackView control panel upper air outlet handle lower air inlet grille Signal Receptor upper air inlet grill with filter power cord hot air exhaust outlet lower air inlet grille water tank continuous dr...

Страница 5: ...airconditionerfollowing theseprocedures a Hold the water tank and draw it out slowly b Removewatertankfloatlidandpackingmaterial from the water tank c Insert the float lid into the water tank by inser...

Страница 6: ...haust duct for a window or sliding door hot air outlet installation NOTE In order to increase the efficiency the exhaust duct should be keep as short and straight as possible The exhaust hose can be c...

Страница 7: ...on if necessary NOTE Whenusingthewindowkitonawindoworslidingdooritwillcausethewindoworslidingdoor not to be properly closed and locked Additional security measurements should be taken CONTROL PANEL AN...

Страница 8: ...re before selecting the operational mode 5 TimerControl Set time to start or to stop the unit When the unit is running the timer will shut off the unit in the number of hours set When the unit is off...

Страница 9: ...Mode a Press the Mode Button until the Auto appears on the LCD display In the Auto Mode the factory set microprocessor controls the temperature and fan speed for optimal comfort NOTE Duringhotdays th...

Страница 10: ...n NOTE When the unit is running on fan mode the exhaust duct is inoperative and is not required OPERATION USING REMOTE CONTROLLER The remote controller provided with the unit may operate this portable...

Страница 11: ...e Transmit key to set time 2 CoolingOperation a Press the On Off key to turn on the remote controller b Press the Mode key until the LCD displays COOL c Press either of key of the Temperature key unti...

Страница 12: ...eration a Press the On Off key to turn on the remote controller b Press the Mode key unit FAN appears on the LCD display c Press the Fan Speed key until the LCD displays the desired fan speed d Presst...

Страница 13: ...eep alarm will sound eight times for 15 seconds The compressorstopsrunningandthefanwillcontinuetoruninthesetspeedforthreeminutesbefore theentireunitautomaticallyshutsoff When the water tank is full ta...

Страница 14: ...wnward c Hold down the drainage spout and then connect the drainagetubingintodrainagespout d Place the other end of the drainage tubing into either an external water tank or the receptor of a condensa...

Страница 15: ...oles in the unit case Push the cover back intoitsoriginalposition f If the filter is torn or unusable order a new filterbycallingthecontactsectionofthis manual 2 Case a Keep the unit from being expose...

Страница 16: ...his unit provides spot cooling or cooling for a room no larger than 350 square feet with standard ceil ingheight There is frost on the evaporator The unit will defrost automatically and return to oper...

Страница 17: ...ATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRE SENTED HEREWITHIN CONTACT INFORMATION Contact For Optional and Spare Par...

Страница 18: ...16 ELECTRIC PRINCIPLE DRAWING KY 32U...

Страница 19: ...S WARRANTY DOES NOT COVER 1 Damage accidentalorotherwise totheairconditionerwhileinthepossessionofaconsumer not caused by a defect in material or workmanship 2 Damagecausedbyconsumermisuse tampering o...

Страница 20: ...re not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to c...

Отзывы: