66666
Function manual and operation method of remote controller
Function manual of remote controller
with each other to complete all kinds of the functions.
This function manual only for D C Inverter air conditioner KFHHP-18. The indoor and outdoor
units of D C Inverter air conditioner have their own main PCB, control diffrent objects and communicate
Main functions for indoor unit
Main functions for outdoor unit
Mode
COOL
DRY
AUTO
HEAT
FAN
Detecting indoor room temp.
dispart voltage resistance( 15K )
Indoor room temp. sensor (15K ),
Indoor pipe temp. sensor (20K ),
dispart voltage resistance( 20K )
Temp. control
Making indoor room temp. reach the preset
temp. rapidly and keep at preset temp.
Remote control signal and manual
key signal manage
Indoor fan
high; med; low
Swing
step motor
Indicator
Buzzer
Timer
Sleep
Memory
Heat turn on in heating mode
( cold air prevention )
Antifreeze Protection in cooling mode
Communicate with outdoor unit
Wave filter and protection
for power supply
Detecting outdoor ambient temp.
Outdoor ambient temp. sensor (15K ),
dispart voltage resistance( 15K )
Outdoor pipe temp. sensor (20K ),
dispart voltage resistance( 20K )
Exhaust temp. sensor (50K ),
dispart voltage resistance( 15K )
Outdoor fan
high; low
Invertible compressor
4-way valve
Indicator
Electric heating belt of compressor
Power module protective detection
Power supply current detection
Communicate with indoor unit
SOLEUSAIR
Содержание KFHHP-18
Страница 1: ...1 208 V 230V R410A Introduction and Features Model Remarks SOLEUSAIR KFHHP 18...
Страница 7: ...Overall and Installing Dimension of Outdoor Unit Unit mm Bolt Nut Wrench Comforstar Plus...
Страница 21: ...8 Exploded View and Components and Parts List Exploded View of Indoor Unit SOLEUSAIR...
Страница 23: ...Exploded View of Indoor Unit SOLEUSAIR...
Страница 24: ...Exploded View of Outdoor Unit SOLEUSAIR...