Water leakage
Wrap of refrigerant pipe connector is
Blockage or breakage of drainage hose
not tight enough
Replace the drainage hose
Re-wrap and make it tight
Abnormal sound and shake
Fan of indoor unit contacts other parts
Adjust fan location
There is foreign substance in indoor unit
Compressor shakes too much
Touch of pipeline of outdoor unit
Touch of inner plates
Touch of outdoor unit fan blade with
Abnormal sound inside compressor
Abnormal electromagnetic sound inside
four-way valve when heating
outer case
Take out the foreign substance
Adjust support washer of the compressor and
Separate the touched pipeline
tighten loose bolts
Tighten connecting screws
Stick shock-absorbing clay between plates
Adjust fan position
Short circuit inside electromagnetic valve.
Replace compressor
Replace the electromagnetic valve
Compressor reverse;abnormal sound
like metal crash
Turn the connection of the two of U; V; W
Indoor unit is mounted in the thin wall
cause syntonic sound
window directly .
Avoid to mount the indoor unit on the steel
To mount the indoor unit in the strong and
and thick wall
Adopt some steps to damp vibration
Содержание KFHHP-18