Operation procedures/pictures
Disassembling the front panel body
Unclench the 3 screw covers and screw off the 3 pieces
of screws that fix the panel body. Unloose the front and
rear clasp
s
to take off the panel body.
As shown in Fig.
7
-4
screw
screw covers
Fig.7-4
Disassembling the electric box cover
Unloose the 3 clasps to take off the electric box cover.
As shown in Fig.
7
-5
cl
clasps
Fig.7-5
Fig.7-6
Fig.7-7
Disassembling the water-tray assy
Unloose the clasp on the left side and unplug the
connecting terminal of the stepping motor.
C
areful
ly
to remove the water-tray assy
because the drainage pipe
is placed here.
As shown in Fig
7
-6,
7
-7
cc
clasp
water-tray assy
connecting terminal
SOLEUSAIR