over the stated value, the compressor will stop, the outdoor fan will delay 30 seconds to stop.
6.1.2.4 FAN mode
In this mode, the indoor fan will run the fan in High, Med, Low and Auto mode. The compressor, outdoor fan
and four-way valve will stop.
In this mode, the temperature setting range is 16~30 .
The unit will adjust the running frequency of the compressor automatically according to the change of ambient
temperature.
6.1.2.5 AUTO mode
In this mode, the system selects COOL, HEAT and FAN mode automatically according to the change of ambient
temperature. The protection function is the same with that of COOL/HEAT mode.
The unit will adjust the running frequency of the compressor automatically according to the change of ambient
temperature.
6.1.3 Other control
6.1.3.1 ON / OFF
Each time the On/Off button of the remote controller is pressed, the On/Off state will switch once.
6.1.3.2 MODE selection
Press the MODE button on the remote controller to select and display the following modes:
AUTO, COOL, DRY, FAN, and HEAT.
6.1.3.3 TEMP. setting button
Each time TEMP + or TEMP - button is pressed, the set temperature will be increased or decreased by 1 .
Adjusting range is 16~30 . In AUTO mode, this button does not function.
6.1.3.4 AUTO key
When the unit is stop, press AUTO key,the unit will run under AUTO mode and the swing motor starts.
When the unit is running, press AUTO key,the unit will be stopped.
Handling switch
AUTO/STOP
6.1.3.5 Timer control
The unit is turned on or off according to the timer set by the remote controller.
6.1.3.6 Sleep control
When the air conditioner is in COOL or DRY mode, after Sleep mode has been set properly, the preset T
set
will
be increased by 1
after the sleep program
ć
has run for 1 hour, and T
set
will be increased by another 1
after 2
ć
hours. T
set
has been increased by 2
totally in two hours. Then the unit will run at this set temperature and at
ć
the set speed.
When the air conditioner is in HEAT mode, after Sleep mode has been set properly, the preset T
set
will be
decreased by 1
after the sleep program has run for 1 hour, and T
ć
set
will be decreased by another 1
after 2
ć
hours. T
set
has been increased by 2
totally in two hours. Then the unit will run at this set
ć
temperature and at the
set speed.
Set temp.T
set
1 h
2 h
Above 2h
T
set
+2
ć
T
set
+1
ć
T
set
1 h
2 h
Above 2h
T
set
T
set
-
1
ć
T
set
-
2
ć
Set temp.T
set
In AUTO or FAN mode, the setting temp. will not change.