background image

 

7

 
 
 
            

Installation Instruction (Continuous) 

 

 

 

 
 

 

 

Содержание KC-45H

Страница 1: ...BTU Room Air Conditioner with Heat Pump OPERATING AND INSTALLATION MANUAL Model KC 45H Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for future refe...

Страница 2: ...UCTIONS 6 11 OPERATING CONTROLS 12 BEFORE CALLING SERVICE 13 WHEN SERVICE IS REQUIRED 14 ANY QUESTIONS 14 THROUGH THE WALL INSTALLATION INSTRUCTIONS 15 16 SPECIFICATION 17 WARRANTY 18 Thank you for se...

Страница 3: ...arranty Service line at 1 888 8 SOLEUS If your problem cannot be resolved by phone contact an authorized Soleus Air brand servicer Contact and service will be at your expense Safety Information Be sur...

Страница 4: ...appliance or light fixture ReceptacleWiring Receptacle wiring must be of adequate size for unit Refer to unit identification plate for exact power requirements Minimum size of wiring based on power r...

Страница 5: ...separately Through the wallinstallationinstructionsareincluded with the outer case These models can be adapted to window installation by purchasing an optional mount ing kit RoomHeatPumps Heatpumpswo...

Страница 6: ...lter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once every week during opera tion Cleanfilterwithvacuumcleanerorwashinwarmwater and mild deter...

Страница 7: ...outdoor coil surface This is the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal condit...

Страница 8: ...properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for...

Страница 9: ...7 Installation Instruction Continuous...

Страница 10: ...piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the...

Страница 11: ...OW A Carefully slide the case into the window and center the case Lower the window behind the top mounting rail Pull the bottom of the case forward so that the bottom mounting rail is tight against th...

Страница 12: ...weak or if the weight of the air conditioner falls between the studs in the wall F Extend the left and right accordion panels to the vertical window sashes Drill pilot holes and attach the top and bot...

Страница 13: ...bottom corners and pull it forward Unhook it from its top hinges and set it aside F Using the tab pull up slightly on the filter to release it and pull it down and out 8 INSTALL THE AIR CONDITIONER IN...

Страница 14: ...GH HEAT Filters and circulates room air with the fan running continuously on high speed Also heats while the compressor or electric heater is running Select this setting for maximum air circulation an...

Страница 15: ...ature Control to cooler setting For heating turn Temperature Control to warmer setting NOISY UNIT Loose front on mounting assembly Weak building construction Water hitting fan blade Unit oversized for...

Страница 16: ...quent failure of unit voids warranty Warranty details are contained in warranty certificate enclosed with unit Keep accurate records of service calls including what was done servicer s name and date o...

Страница 17: ...m side to side Use wood shims between sides of case and finished opening especially where case is secured to opening to prevent warping or distorting Check installed case for distortion using carpente...

Страница 18: ...se is properly positioned in opening use wood shims to fill any gaps between case and finished opening especially in area where case will be secured to opening Take care not to warp or distort case wh...

Страница 19: ...e Highside 340 P S I Cooling AMPS 9 7 8 9 Cooling Watts 1955 2000 Cooling EER 9 0 Heating AMPS 8 8 8 3 Heating Watts 1790 1850 Heating EER 9 2 Electric Heat AMPS 15 6 16 Electric Heat Watts 3600 Air F...

Страница 20: ...ect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized servi...

Отзывы: