WARRANTY 

 

One Year Limited Warranty 
 

Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of 

defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) 

year from the date of original retail purchase in the United States. 

 

If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of 

charge within a reasonable time after the unit is returned during the warranty period. 

 

As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a 

copy of the original purchase invoice. 

 

THIS WARRANTY DOES NOT COVER:

 

• 

Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in 

material or workmanship.  

• 

Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions 

in the instructions. 

• 

Damage to the finish of the case, or other appearance parts caused by wear. 

• 

Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-

tional Inc. 

• 

Freight and Insurance cost for the warranty service. 

 

ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO 

ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY

. SOLEUS INTERNATIONAL INC.

  

DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT 

SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR 

BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT. 

 

This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-

vaged, or refurbished products. 

 

As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow  

limitation on implied warranties, the above limitations and exclusions may not apply to you.  This warranty gives you 

specific legal rights, and you may also have other rights that vary from state to state. 

 

For Technical Support & Warranty Service 

Please Call (888) 876-5387  

 

Or Write To: 

Soleus International Inc. 

20035 E. Walnut Dr, North. 

City of Industry, CA 91789 USA 

 

  www.soleusair.com

 

 www.greeusa.com

 

 15 

Содержание GM-PAC-08E3

Страница 1: ...8 000 BTU Portable Air Conditioner Operating Instructions Model GM PAC 08E3 ...

Страница 2: ...anual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start o...

Страница 3: ...table Air Conditioner Exhaust Hose 1 Exhaust Hose Adapter 1 Window Kit Adapter 1 Hose Adapter 1 Remote Control AAA Batteries 2 batteries Window Kit 3 Sliding Panels 4 screws 1 single hose panel 2 extension panels Drain Hose Assembly drain pipe clamp hose clip rubber plug screw Owner s Manual Model GM PAC 08E3 Power Supply Ph V Hz 1 115 60Hz Dehumidifying Capacity Pints Day 38 Rated Cooling Capacit...

Страница 4: ...ed and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If a test is performed ...

Страница 5: ...PRODUCT DIAGRAM Control Panel 5 Louvers Louver Guides Casters Power Cord Filters Upper Air Intake Lower Air Intake Remote Control Holder Air Exhaust Vent ...

Страница 6: ... grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise Mount the exhaust hose onto the back of the unit by locking the hose adapters into place For maximum ...

Страница 7: ...flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 angles like the pictures above and below Multiple bends will decrease performance and effi ciency This installation is OK The is a poor installation 26 22 ...

Страница 8: ... or Dry mode When using the unit as a fan it is not necessary to keep the exhaust hose and window kit connected to the unit 3 Temperature Select the desired temperature by pressing either or key when using the unit in cooling mode 4 Louver Direction This unit has 4 Way directional louvers Use the louver guides to direct air where cooling or fanning is needed most 5 Bucket Full When the unit cannot...

Страница 9: ...Cool Dry Cool Dry ...

Страница 10: ...air When the room temperature is between 68 F 73 F the air conditioner will operate in Fan mode if it was previously selected or dehumidifier mode if another mode was used previously to remove humidity from the air as well as some cooling to help lower the room temperature When the room temperature is between 74 F 79 F the air conditioner will always operate in dehumidifier mode When the room temp...

Страница 11: ...e instructions below 1 Remove the pre installed Drain Cap from the unit See Below 2 Attach the Clamp with the provided Screw See Below 3 Attach the Drain Hose to the Drain Port using the Drain Hose Clip Insert the Drain Plug into the free end of the Drain Hose and guide the Drain Hose through the Clamp Once finished the unit can be easily drained by removing the drain plug and guiding the drain ho...

Страница 12: ...ried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess wate...

Страница 13: ...ESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Evaporator is frozen Make sure there are no curtains blinds or furniture blo...

Страница 14: ...lug for 10 minutes and then turn on the unit If E5 is still dis played contact customer service TROUBLESHOOTING CONT The LED Display is showing H8 The backup water tank is full Drain the water tank If the H8 I still displayed after the water tank has been emptied con tact customer service 14 ...

Страница 15: ...ance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR I...

Страница 16: ...66129906894 ...

Отзывы: