MAINTENANCE

 

 

Note:  Make sure power is off and the power cord is not plugged into an electrical outlet 
prior to performing any maintenance on the unit. 
 
Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce.  It is      
recommended to clean the filter once every two weeks or as needed. 

1)  Remove the filter from the filter compartment on the left and back of the unit. 
2)  Wash the air filter by immersing it gently into warm water with a neutral detergent.  Rinse the 

filter and dry it thoroughly out of sunlight. 

3)  Slide the filter back into the filter compartment after it is thoroughly dried. 
4)  If the filter is torn or unusable, order a new filter by calling the customer service number on the 

warranty page of this manual. 

Clean the unit Housing 

1)   Keep the unit from being exposed directly to the sun to prevent color fading. 
2)   Clean the surface with a damp cloth and dry it with a soft towel. 

Storing the Unit for an Extended Period of Time or Transporting the unit 

1)   Empty any excess water by unplugging the water drainage stop in the back of the unit (located 
at the bottom). 
2)   Unplug the unit. 
3)   The unit should be stored in a cool dry place. 

 
 

 

 
 
 
 

 
 
 
 
 
DISCLAIMER 

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE 

THE PRESENTATION OF THE MANUFACTURER.  SOLEUS 

HOME COMFORT

 HAS NOT CONDUCTED INDE-

PENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN. 

Содержание EL-PAC-08E9

Страница 1: ...8 000 BTU Portable Air Conditioner Operating Instructions V021014 Model No FE 08BA 3092402 ...

Страница 2: ...ner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be conne...

Страница 3: ...g temperature or lower than the minimum operat ing temperature the air conditioner may not work properly PACKAGE CONTENTS MODEL NUMBER FE 08BA COOLING CAPACITY 8 000 BTU H DEHUMIDIFYING CAPACITY 38 pts per Day COOLING POWER USAGE 760 Watts 6 7 Amps AIR FLOW VOLUME 200 CFM POWER SOURCE 115 V 60 HZ SOUND PRESSURE LEVEL 46 dB A PRODUCT WEIGHT 50 Lbs OPERATING TEMPERATURE 60 8 107 6 11 75 W 13 75 D 31...

Страница 4: ...ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit should trip cutting power to the air conditioner When this occurs 3 Press RESET button to restore power to the machine Once power is restored the LED light will turn on agai...

Страница 5: ...T DIAGRAM Casters Louvers Remote Control Signal Receptor Control Panel on top Filter Compartment Remote Control Evaporator Air Intake Condenser Air Outlet Condenser Air Intake Drain Port Drain Hole Rubber Plug ...

Страница 6: ...lass doors up to 7 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose counter clockwise Screw the hose adapter onto the other end of the exhaust hos...

Страница 7: ...he opening Figure D If necessary mark the kit and cut one end down to properly fit the opening Figure E F 5 Attach the window kit adapter to the window kit Figure G 6 Place the window kit back into the window and attach the exhaust hose to the window kit adapter Figures H I Close the window tightly Figure J Your portable Air Conditioner is now ready to cool NOTE When using the venting system keep ...

Страница 8: ...Screws A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 and connect it to Hose Panel C1 by placing the Sliding Track Panel D over the Track Screw A on Hose Panel C2 6 The Hose Panels C1 C2 should now be connected using the Sliding Track Panel D 7 To comple...

Страница 9: ... mode The temperature indicator flashes to display the desired temperature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The tem perature indicator display shows temperature in Celsius or Fahrenheit Press the and simultane ously to change between Celsius and Fahrenheit 4 Bucket Full when the unit can not evaporate the collected ...

Страница 10: ...ROL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from the image above ...

Страница 11: ...p and there will not be a fan speed displayed on the remote control 4 Temperature Setting When the unit is in Air Conditioner mode you can select your desired tem perature Press the or to select your desired temperature setting The temperature on the LCD display on the remote control will increase or decrease accordingly Pressing the and buttons simultane ously will change the temperature select b...

Страница 12: ...cy NOTE When the unit is running on cooling mode the exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the dehumidifier mode icon light up on the control panel...

Страница 13: ...rainage hose to the back of the unit to aid in drainage into the pan Once the condensate tank is drained the unit will begin working within a few minutes The emergency condensate tank is approximately 1 5 Liters of water An other option is to purchase a small hose from a hardware store that can fit around the 5 8 drain plug on the back of the unit and drain the unit into a gravity drain or larger ...

Страница 14: ...ughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any exce...

Страница 15: ...ppearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home Comfort Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS HOME COMFORT DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDEN...

Отзывы: