No heat 

1.

 

Power is off. 

2.

 

Set temperature is in 
improper position 

3.

 

Connector has fallen off. 

4.

 

Heater is defective 

5.

 

Fuse is open. 

6.

 

Control panel is not 
working. 

Check the circuit 
Adjust the set value 
 
Tighten the plug. 
Change the heater. 
Change the fuse. 
Change the circuit panel. 

The fan doesn’t operate 

1.

 

Control panel is faulty. 

2.

 

The capacitor of fan 
defective. 

3.

 

Fan defective. 

Change the panel. 
Change the capacitor. 
 
Change the fan. 

Unusual sound or heavy 
shaking 

1.

 

Installation of the 
air-conditioner too 
gradient. 

2.

 

Fan touches with other 

 hardware. 
3.

 

The connective pipelines 
collide

 

with each other. 

4.

 

The part becomes flexible. 

Check Installation. 
 
 
Adjust the fan position. 
 
Adjust the position between 
the pipelines. 
Tighten screws. 

 
Installation 

1. Installation 

preparation 

If you need to install the air-conditioner on already existing roof vent, the measure of vent 
must reach 14

×

14 (in). If it is not enough of this measurement, you must extend this 

measurement. If it is larger than this measurement, you must make a wood frame for the vent 
to meet above measurement. 
The gradient of install the platform must no more than 5

°

. If greater than 5

°

 it can be 

influenced that condensation water of the air conditioner could overflow. 

      You must avoid any wire and any pipeline before incision. 
 
2.

 

Please directly install the top of the air-conditioner on the placket and make windward face 
toward the front of the vehicle, condenser toward the back of the vehicle. Put the seal  
between air-conditioner and placket, and you can sight the four M10 install bores in the 
air-conditioner bottom. To those irregular coarse roofs you must have

 sealant seal up all gaps 

in order to prevent rainwater infiltrating into room. 

 
 
 
 

 

7

Содержание air-condition

Страница 1: ...Please read Owner s Manual carefully before operating the unit ...

Страница 2: ...oad Current A 14 8 Air Flow Volume CFM 412 235 Power Supply 115VAC 60HZ 1Phase Operational Range Cooling F 61 to 115 Operational Range Heating F 17 to 90 Inside The Room dB A 51 Noise Level Outside The Room dB A 62 Refrigerant Amount ounce R22 42 Top Mount Unit 103 5 Net Weight Indoor Unit lbs 7 5 Top Mount Unit In 44 W 28 3 4 D 14 3 4 H Assembled Dimensions Indoor Unit In 21 1 2 W 20 1 2 D 3 1 4 ...

Страница 3: ...lower system protection cover tunnel and the control panel in main cabin Character 1 Instant cooling adjustable temperature It can reduce the environment temperature in a short time in order of passenger s demand 2 Continuously running in adverse condition 3 Lengthy continuously running time in acid and alkali condition 4 The Width Height capability The appearance and assembly size keep the same w...

Страница 4: ...You can switch it in FAN state COOL state and HEAT state 3 Temperature setting button TEMP Through buttons and you can increase and reduce the setting temperature in the room 4 Fan speed switch button SPEED You can switch fan speed in HIGH or LOW 5 Temperature showing temperature In holding state control panel shows present indoor temperature The control panel shows temperature in setting state If...

Страница 5: ...The scheme of refrigeration system COMPRESSOR THROTTLE FAN EVAPORATOR CONDENSER 4 ...

Страница 6: ... C1 T PT 110VAC 60HZ S R C PE PE N L 4 FU3 KA1 2 3 MF C2 FU2 KA1 MC 1 CONTROL PANEL OPERATE PANEL on com HEAT TRANS OUT TRANS IN C B A GND 5V G DAT CLK REC KEY WAT1 WAT2 SENSOR1 SENSOR2 L L N N N L FAN N H FAN HEATER BL RE YE YE GR WH WH BL RE GR YE GR 5 ...

Страница 7: ...he power is lower than 97V 2 You are using an extension cord for the unit 3 The system leaks Fluorine 4 Button ON OFF failure 5 Set the temperature to the abnormal position 6 Compressor not working 7 The sub cooling of compressor is protected and does not work 8 Capillary is blocked Adjust the voltage range into normal demand Do not use an extension cord Call repair technician Replace button ON OF...

Страница 8: ...allation preparation If you need to install the air conditioner on already existing roof vent the measure of vent must reach 14 14 in If it is not enough of this measurement you must extend this measurement If it is larger than this measurement you must make a wood frame for the vent to meet above measurement The gradient of install the platform must no more than 5 If greater than 5 it can be infl...

Страница 9: ...ith the hole on the top of the air conditioner and tightly connect with 4 M10 special screw 4 Install canvas pipe You must make the flange of the canvas pipe align with air outlet of the top of air conditioner and connect them with screw gasket spring gasket and nut 8 ...

Страница 10: ...crew Caution It can be rotated from 90 to 90 b Installing the canvas pipe underparts You must put into metal flange from canvas pipe under part and tightly nip main vent pipe and connect with ST4 2X16 screw The surplus part is cut out c Install covers board of vent pipe and indoor main cover board d Connect indoor plastic and gold with two M4 10 screws gasket and spring gasket 9 ...

Страница 11: ...o make sure unit is installed correctly and safe 2 Switch on the power operate the air conditioner according to above methods If it runs improperly for example abnormal noise running current too high or no temperature please check owner s manual 10 ...

Страница 12: ...3 Clean up the installing rubbish and restore decoration to original decor 11 ...

Страница 13: ...ion or repair by the user abuse misuse neglect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encountered Soleus agrees to provide service information sell repair...

Отзывы: