Systems and schedulded
maintenance
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
29
Operator’s Manual Marine
generators sets
5.6.
Cooling system
The genset cooling system is based on coolant circulation controlled by centrifugal pump with
thermostatic control and heat exchanger, where the coolant is refrigerated by sea water. Moreover,
the exhaust manifold is cooled also by sea water.
Coolant specifications
It is recommended use Solé Diesel 50% coolant or another coolant with similar specifications.
On the other hand, distilled water with an anti-freezing agent is also suitable. The anti-freezing agent
concentration according to operating conditions is specified in anti-freezing agent package labels. It is
advisable select the anti-freezing agent concentration based on a temperature approx. 5ºC under the
actual atmospheric temperature.
Other genset coolants may affect warranty coverage, cause an internal build-up of rust and
scale and/or shorten genset life.
PIECE
ELEMENT
1
Pump prime line
2
Coolant pump
3
Oil cooler
4
Cylinder cooling cirucit
4A
Cylinder heat cooling circuit
5
Expansion tank
6
Wet exhaus manifold
7
Turbocharger
8
Heat exchanger
9
Seawater pipe
10
Wet exhaus elbow
11
Coolant pump inlet
12
Thermostat
PIECE
ELEMENT
1
Sea water pump
2
Air cooler (only in 115 GT/GTC
and 120 GTA/GTAC
3
Heat exchanger
4
Wet exhaust elbow
Model
Coolant circuit
capacity (L)
85 GTC / 100 GTAC /
115 GTC / 120 GTAC
DNV
17,5
Coolant circuit description
Sea water circuit description
Never mix different types of coolants. This may adversely affect the properties of the