5 Installation
5.3.2 Flue gas pipe facing upwards (optional)
For dimensions see
The boiler is supplied from the factory with the ID fan
facing the back. To align the ID fan upwards, proceed
as follows:
►
Separate perforated opening from the upper
cover (e.g. with wire cutters).
►
Release
1
3 x hex bolts.
►
Turn the housing 90 degrees to the left.
►
Fasten bolts.
Abb. 2-23: Turn ID fan
►
Fit flue gas pipe and attached extension.
Abb. 2-24: Flue gas pipe upwards, including attached extension
►
Cut the insulation of the flue gas pipe a bit at the
bottom, so that it conforms to the boiler insu-
lation.
5.3.3 Flue gas pipe: Hole for emission mea-
surement
►
Make the hole for the emission measurement
according to the following images (recom-
mendation according to standard).
►
If these specifications cannot be implemented,
then make the measuring point after a calming
section, i.e. after the longest straight section of
the pipe. The pipe orientation (horizontal, ver-
tical, oblique) plays no role in this case.
►
In any case, place the measuring point before
any existing draught stabilisers.
You can find the function for carrying out the emission
measurement in the boiler operation manual,
keyword:
Chimney sweep function.