3 Warranty, guarantee, liability
4.5 Accessories
Lifting aid
–
Optional accessories for carrying/moving the boi-
ler.
–
Item 6144
Abb. 2-1: Lifting aid mounted
Extension pack for operation as a room-sealed
appliance (RS)
–
Optional accessories for operation of the boiler as
a room-sealed appliance.
–
Item 67250
–
Further information can be found in the boiler's
installation manual.
Abb. 2-2_RLU Erweiterung
Extension for flue gas pipe connection
–
Optional accessories for extension of the connec-
tion to the top of the boiler.
–
Further information can be found in the boiler's
installation manual.
4.6 Type plate
4.7 CE declaration of conformity
The conformity of the product is declared by the
manufacturer in accordance with the Machinery Direc-
tive 2006/42/EC; the documents are available for
inspection at the manufacturer.
The product corresponds to Directive 2011/65/EU
(RoHS 2) and does not use any materials containing
asbestos. The product does not contain any PCB or
mercury.
4.8 Safety devices
Heat dissipation
–
This function of the boiler control is a safety
device that prevents overheating of the boiler.
–
Functioning: If the boiler temperature exceeds the
Heat dissipation maximum boiler temperature
[1]
parameter, all pumps relating to the connected
devices (e.g. heating circuit, DHW tank, buffer
tank) will be switched on and the heating circuit
mixing valve opened. In this way, energy is drai-
ned from the boiler and it may be possible to pre-
vent other safety devices tripping.
–
If the boiler temperature falls below the set
Heat
dissipation maximum boiler temperature
minus
1°C again, the pumps and mixing valves will be
operated in standard mode again.
[1] You can find the parameter in
Service menu
|
System para-
meters
button |
General settings
button.
6
Operation manual
pelletelegance