16 Perform emissions measurement
16 Perform emissions mea-
surement
–
The emissions measurement at the boiler is a
legal requirement and must be performed by qua-
lified personnel on a regular basis.
–
For more information, consult the relevant chim-
ney sweep and your heating engineer.
–
When performing the emission measurement, the
boiler control's
chimney sweep function
must be
used.
Chimney sweep function
The chimney sweep function is available in the boiler
operating mode screen
Notes on chimney sweep function
–
May only be performed by qualified personnel.
–
Do not open the boiler door during the mea-
surement.
–
Ensure sufficient heat removal for the boiler (e.g.
energy removal to buffer tank or heating circuit).
–
The removal of heat is increased by opening the
heating circuit mixing valve and by switching on
the heating circuit pumps.
Start the chimney sweep function
►
Press the
button.
Ä
The prerequisites for enabling a mea-
surement are tested.
Abb. 2-61
►
As soon as
Measurement enable
appears in the
status bar, the measurement can be started.
–
The chimney sweep function remains active for a
period of 40 minutes. Before this period expires, a
message allowing extension of the period by 30
minutes is displayed.
–
To abort the function prematurely, switch to a dif-
ferent boiler operating mode.
16.1 Emission measurement for external
boilers
If necessary, use the menu
output test heating circuit
to carry out the emission measurement on an
external boiler. In this menu, the electrical outputs for
the remote boiler, 3-way motor valve as well as for
the heating circuit pump and heating circuit mixing
valve can be switched on/off manually.
17 Filling pellet storage area
Switch off the boiler before filling
i
For safety reasons, switch off the boiler
15 min. before filling (blowing in) the pellet sto-
rage area.
If item
House connection box for pellet filling
(item no. 6678) is used, this is done auto-
matically.
Operation manual
maximus L
41