15 Maintenance (and cleaning)
If the
Solar yield in the room
function reduces the tem-
perature(s) due to good weather being forecast, then
the weatherman icon appears in the main heating cir-
cuit menu.
14.3 Domestic hot water
Abb. 2-55
1 DHW range for the boiler
octo
plus
2 DHW tank / domestic hot water area 1 to 4
Activate the
weather influence domestic hot water
function only if the DHW tank/domestic hot water
area is heated by a solar power system, or is charged
from a buffer tank that is heated by a solar power sys-
tem.
Good weather forecast delays the start of the burner
in the event of a request from the DHW tank/domestic
hot water area.
The bar can be used to set the duration of the request
delay for each DHW tank/domestic hot water area
individually.
0% = no delay to burner start..
100% = maximum delay to burner start in the event of
good weather being forecast.
If the function delays the burner start due to good
weather being forecast, then the weatherman icon
appears in the main domestic hot water menu.
The green column indicates the delay. When 100% is
reached, the burner starts.
14.4 Buffer tank charging
Abb. 2-56
This menu
1
is only visible when a buffer tank is ena-
bled in the boiler control.
In the event of good weather being forecast, the buf-
fer tank is charged for a shorter time within the
release time.
The bar
2
can be used to set the level of influence for
each buffer tank individually.
0% = if the burner has started and the buffer tank is
within a release time, then the buffer tank is com-
pletely charged. The charge request is fulfilled when
the
buffer cylinder temperature bottom
has reached
the
maximum buffer cylinder temperature bottom
(in
the buffer tank main menu).
100 % = if the burner has started and the buffer tank
is within a release time, then the buffer tank is not
completely charged. The charge request is then
already fulfilled when the
buffer cylinder temperature
bottom
has exceeded the
minimum buffer cylinder
temperature top
(in the buffer tank main menu).
15 Maintenance (and cleaning)
i
Regular maintenance of the heating system is
a prerequisite
–
for permanently reliable functioning of the
boiler,
–
for energy-saving and environmentally fri-
endly operation of the boiler,
–
for long service life of the boiler.
38
Operation manual
maximus L