7 Electrical connection
7.4.3 Connect ash extraction burner
►
Connect automatic ash extraction motor
1
to
A1:X16
Abb. 2-55
7.4.4 Connect rotary actuators
The bus cables coming from the control cabinet (clam-
ping area X10) of the heat exchanger include the fol-
lowing components when fully installed:
–
Rotary drive for primary air
(connect on
site)
–
Rotary drive for secondary air
(connect on
site)
–
Rotary drive for flue gas recirculation
–
Induced draft fan
►
Join MATE-N-LOK connector
1
for primary air,
X200
►
Join MATE-N-LOK connector
2
for secondary
air,
X201
Abb. 2-56: Connect bus cable
Connection
X20
x
(rotary drive for primary air and
secondary air)
Order of bus slaves
7.4.5 Connection for electronic modules
CAN-OUT interface X6
See power element_A3 (optional A4)
Pin
Signal
Function
1
+24 V
+24 V supply
2
CAN A
CAN signal low
3
CAN B
CAN signal high
4
GND
Ground
5
SH
Shield (ground)
36
Installation manual
maximus L