Chapter 4: SMI User Interface
Safety and Monitoring Interface Installation Manual – MAN-01-00067-2.1
25
25
Server Communication Status
S e r v e r : L A N < S _ O K >
S t a t u s : x x x x x x x x < O K >
< E R R O R M E S S A G E >
Server
: The method of connection to the SolarEdge monitoring server
S_OK
: The connection to the SolarEdge monitoring server is successful (appears only if the inverter is
connected to the server).
Status
: Displays OK if the inverter established a successful connection and communication with the
specified server port/device (LAN, RS485, ZigBee module, or external GSM modem).
xxxxxxxx
: Eight-bit Ethernet Communication Connection Status: A string of 1s and 0s is displayed.
1 indicates OK, 0 indicates an error. Refer to
IP Status
This window describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access
Control) of the
IMS
.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
ZigBee Status
This window describes the ZigBee configuration:
P A N : X X X X X
C h : X X / X X X X R S S I : < L >
I D : X X X X X X X X
M I D : X X X X X X
RSSI
: The receive signal strength of the closest ZigBee in the SolarEdge system. L = low, M = medium,
H = high and - = no signal.
PAN ID
: The ZigBee module pan ID.
Ch
.: The ZigBee module channel.
ID
: The ZigBee module ID.
MID
: The ID of the coordinator (master) ZigBee module. This field is shown only in devices with
router (slave) ZigBee modules. This field appears after a successful ZigBee association. If a ZigBee
module is not connected, a
No ZigBee
message is displayed instead of the
MID
field.
Communication Ports Status Window
D e v P r o t # #
R S 4 8 5 - 1 < S E > < S > < - - >
R S 4 8 5 - 2 < S E > < M > < - - >
Z i g B e e < S E > < M P S > < - - >
Dev
: The type of device that was configured to a specific port (based on the port’s functionality), as
follows:
SE
: SolarEdge device (default)
MTR
: Revenue meter
INV
: Non-SolarEdge inverter
LGR
: Non-SolarEdge logger