Status Screens - Operational Mode
During normal operation pressing the external LCD light button turns on the LCD
backlight.
Additional presses display the following screens one after the other.
Initial Status
V d c [ V ] I d c [ A ] P d c [ W ]
1 4 . 1 x x x . x x x x x
P _ O K : X X X / Y Y Y < S _ O K >
O F F
Vdc [V]
: The DC output voltage
Idc [A]
: The DC output current
Pdc [W]
: The DC output power
P_OK: XXX/YYY
: There is a connection to the power optimizers and at least one
power optimizer is sending monitoring data. XXX is the number of power optimizers
for which telemetries have been received in the last two hours. YYY is the number
of paired power optimizers identified during the most recent pairing process. If XXX
and YYY are not equal, there may be a problem in one or more power optimizers.
S_OK
: The connection to the SolarEdge monitoring platform is successful .
ON/OFF
: Indicates the position of the SMI ON/OFF switch.
SMI-180 Installation Guide MAN-01-00157-1.1
39
Status Screens - Operational Mode
Telemetry Status
This screen displays the last power optimizer telemetry received. The display changes as
each power optimizer sends its telemetry.
In order to verify proper installation, the installer may view the Telemetry window for
some time in order to observe the power optimizers' report process.
M o d u l e :
1 0 2 8 8 0 6 3 1 B
E n e r g y [ W h ] : 5 6 . 7
V d c _ O [ V ] : 4 0 . 0
V d c _ I [ V ] : 3 8 . 3
I _ i n [ A ] : 7 . 8
T e m p [ C ] : 2 8 . 0
Module: Power optimizer serial number
Energy: power optimizer energy