Verifying Proper Operation
A status screen similar to the following appears on the SMI LCD panel:
V d c [ v ] I d c [ a ] P d c [ w ]
4 3 0 . 1 X X X . X X X X X P _ O K :
0 0 8 / 0 0 8 O N
1. Verify the following:
The green inverter LED is steadily lit.
The ON/OFF indicator on the LCD panel reads ON.
P_OK: XXX/YYY: There is a connection to the power optimizers and at least one
power optimizer is sending monitoring data.
Vdc [v]: Specifies the DC input voltage, which should be within the DC voltage
operating range of the SMI.
Idc [A]: The DC input current
Pdc [w]: Specifies the expected DC output power.
2. Take note of the serial # on the SMI label. This information is used in the SolarEdge
monitoring platform to identify this SMI and is needed when opening a new site in
the monitoring platform.
SMI-180 Installation Guide MAN-01-00157-1.1
29
Verifying Proper Operation