Clamping
the
Smart
Half-cut
Cell
Mono
PERC
Module
Modules
can
be
laid
on
rails,
either
on
the
long
side
of
the
frame
(See
Figure
6
).
Figure
6:
Connecting
the
SPVxxx-R60LWMG
/SPVxxx-R60LBMG
Modules
by
clamps
to
a
frame
Attach
each
aluminum
mounting
clamp
with
an
M8
(5/16")
bolt,
nut.
Tightening
torque
should
be
within
17~23
Nm
(12.5~17.0
ft-lbs)
coarse
thread
bolts.
Secure
each
clamp
by
attaching
a
plain
washer,
spring
washer,
and
nut,
in
that
order.
Figure 7: Attaching mounting clamp
Ensure the clamps overlap the module frame by at least 5 mm (0.2 in)
Ensure the clamps overlap length is at least 40 mm (1.57 in)
Ensure the clamp’s thickness is at least 3 mm (0.12 in)
NOTE
For configurations where the mounting rails run parallel to the frame,
precautions should be taken to ensure the bottom flange of the module frame
overlaps the rail by 15 mm (0.59 in) or more.
Chapter 2: Mechanical Installation
13