![SolarEdge 3000A-US Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/solaredge/3000a-us/3000a-us_installation-manual_1313693046.webp)
Chapter 6: User Interface
SolarEdge Installation Guide – MAN-01-00002-1.7
44
Communication Ports Status Window
D e v P r o t # #
R S 4 8 5 - 1 < S E > < S > < - - >
Z i g B e e < S E > < M P S > < - - >
##
:
The total number of slaves detected on the specific port
DEV
: The type of device that was configured to a specific port (based on the port’s functionality), as
follows:
SE
: SolarEdge device (default)
MTR
: Revenue meter
LGR
: Non-SolarEdge logger
PROT:
The protocol type to which the port is set:
For a SolarEdge device:
o
S:
SolarEdge slave
o
M:
SolarEdge master
o
P2P:
ZigBee point-to-point
o
MPM:
ZigBee multipoint master (for a ZigBee coordinator module)
o
MPS:
ZigBee multipoint slave (for a ZigBee router module)
For a
revenue meter
reader, refer to the supported revenue meters page at
http://www.solaredge.com/articles/se-supported-devices
For a non-SolarEdge logger:
SS:
SunSpec