TROUBLESHOOTING

   • The LED should light when the furnace blower is running.

   • Both lamps use the same multivoltage ballast.

If the LED does not light:  1. Check to be sure there is power to the unit.

 

 

 

2. Be sure lamp connectors are fastened securely. 

 

 

 

3. If the LED still does not light, replace lamp(s).

 

 

 

4. If still not operating, replace ballast.

Note: Standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

WARRANTY

    All electronic components carry a lifetime warranty to the original homeowner.  In addition there is a four-year 

warranty from the date of installation for any subsequent owner.  The manufacturer reserves the right to send 

replacement parts or to replace the unit at its discretion.  This warranty does not cover any labor or damage 

resulting from improper installation or abuse. Use of any lamp other than the manufacturer’s lamp designed for 

this device will void the warranty.

   The original lamps are warranted for a period of two years. This warranty does not cover lamps broken during 

shipping, installation or as a result of improper handling.

   All returns are routed through your contractor/wholesaler and must be approved and accompanied by an RGA#.  

Please call 800-578-7873 and we will guide you through the return procedure. 

   This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

MAINTENANCE

This maintenance schedule is only a guideline, determined by average conditions. Actual  conditions will dictate 

the frequency of cleaning and/or replacement of lamps.  Do not touch the glass portion of the lamps with bare 

hands because oils from the hands can cause “hot spots” which reduce lamp life.  Handle either by the end caps or 

use a soft cloth.  If  you accidentally touch a lamp, clean it using a soft cloth dampened with rubbing alcohol.
CLEANING THE LAMPS -  Recommended interval: 12 months  (Follow the procedure below)

 

 

 

     Replacement lamps are available through your HVAC contractor.

REPLACING THE LAMPS - Recommended interval: 24 months. (Follow procedure below excluding #6.) 

Note: Standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

1. Disconnect power to the unit.
2. Remove the cover from the unit by removing the four machine screws. Remove the oxidation control (Figure A).
3. Unplug the lamp from each lamp connector.
4. Remove lamp holders using a 1/4 size nut driver (Figure A).
5. Remove each lamp by grasping the end cap and extract carefully.
6. Using a soft cloth moistened with rubbing alcohol, wipe down each lamp.  If there is a large build-up of dust 

    particles, you may wish to use a can of air first.  Always handle lamps by end caps.
7. Slide one lamp back into lamp opening. Reinstall lamp holder.
8. Repeat step 7 for second lamp.
9. Plug each lamp into the corresponding lamp connector.
10. Align the oxidizing control with adjustment linkage and replace cover. (Figure A).

      Secure cover using the four machine screws.
11. Restore power to unit.

For Technical Support Call (800)578-7873      © 2018 Form GEN 823 (04/18)

The following parts are included:  • FM2 Unit

 

 

 

 

 

• Germicidal Twin H Lamp (packed in lamp box)

     • 

Four 

Sheet 

Metal 

Screws

     • 

Installation 

maintenance 

instructions

     • 

Alcohol 

pad 

for 

cleaning 

lamps

     • 

Strain 

relief 

connector

When installing and using this electrical equipment, basic safety precautions

should always be followed including the following:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Minimum living space for this product is 1,200 square feet.

3.

 Always be sure the unit is unplugged during installation or service procedures.

4.

 

The ultraviolet light produced by the UV lamp is harmful to your eyes.  Do not look directly at 

    the lamp.  Should it become necessary to view the lamp, use UV-protected sunglasses.

Lors de l’installation et de l’utilisation de cet équipement, des précautions devront être suivies.

1- Lire et suivre les étapes attentivement.

2- Espace minimum d’une habitation pour ce produit est de 1,200 pi. carrés

3- Assurez vous de toujours débrancher avant l installation ou le service.

4

Ne pas regarder la lampe directement avec les yeux. Si nécessaire de le faire, 

    veuillez porter les lunettes de soleil contre les rayons U.V.

IMPORTANT: SAFETY INSTRUCTIONS

Important: Instructions de securité

3099107

 

FM2-12,  FM2-16 

MultiVoltage Oxidizing UVC System

  

Installation & Maintenance Instructions

UNPACKING THE UNIT

Each unit is shipped with the 5” lamp installed and the germicidal 

lamp placed in a box with protective packaging.  Carefully 

remove lamp from the tube taking care to not touch the glass 

portion of the lamp with bare hands. Oils from the hands can        

cause “hot spots” which reduce lamp life.  Handle by the end 

caps or use a soft cloth.  If you  accidentally touch a lamp, clean it 

using the included alcohol cleaning pad or a soft cloth dampened 

with rubbing alcohol.  The lamp is fragile and proper care must be 

taken when removing from packaging.