Main Screens (Touchscreen)
Detailed Volts View
•
Top row = Total power for column
•
Middle Row = Line 1/PV1 voltage, Amps, and Watts
(note: PV Voltage not to exceed 500V)
•
Bottom Row = Line 2/PV2 voltage, Amps, and Watts
(note: PV Voltage not to exceed 500V)
•
Batt Temperature will show -20°C if the temperature
sensor is not connected. Batt SOC % = % batteries are
charged
•
DC Temp = Temperature of DC conversion electronics
o
Batt
AC
o
PV
Batt
o
AC
Batt
•
AC Temp = Temperature of AC conversion electronics
o
Batt
AC
o
PV
AC
•
Grid Column
o
If selling to the Grid, Grid Watts = negative
o
If buying from the Grid, Grid Watts = positive
o
HM = power detected by the external current
sensors on the entire home L1 & L2
o
LD = power detected using internal sensors on AC grid in/out breaker
PV Graphical View
A.
Displays power production over time for the PV array
B.
Use up/down buttons to navigate between days
C.
Month view, Year view, and Total view
Note: Reversed Grid Watt values may
indicate incorrectly installed current sensors
(reversed polarity). See Page 38.